Tyco Safety Products/Sensormatic AMSUSUPB Manuel D’Utilisation
ULTRA 1.5 METER ABS PEDESTAL SYSTEM
8200-1048-06, REV. A
INSTALLATION GUIDE
36 of 44
*8200-1048-06*
Appendix C: Connecting an UltraLink
The following section describes how to connect an UltraLink to the Ultra 1.5 meter ABS Pedestal System.
You can connect an RS-485 network device such as an UltraLink to the Ultra 1.5 meter ABS Pedestal System
at P24 on the main controller board, using pins 1, 2, and 8.
at P24 on the main controller board, using pins 1, 2, and 8.
Figure 23. Connecting the system to an UltraLink
P24
Main controller board
on primary pedestal
on primary pedestal
CBC-4020UltraLink
Grounding Post
J6
AC to 12Vdc
Transformer
Comm Cable 6003-0210-01/02
UltraLink
I/O Board
Comm 1