Tyco Safety Products/Sensormatic AMSUSUPB Manuel D’Utilisation

Page de 44
ULTRA 1.5 METER ABS PEDESTAL SYSTEM 
           8200-1048-06, REV. A
 
INSTALLATION GUIDE 
        
40 of 44 
 
            
 
*8200-1048-06*
 
Figure 25. LDM II Ports 1-4 
 
Ports 1-4 
4.  Supply power to the pedestals and the UltraLink. 
5.  Test the system with an active EAS tag or label to verify that the pedestal is operational.  
Configuring a Local Device Manager 
The following section describes how to configure a Local Device Manger to the Ultra 1.5 meter ABS Pedestal 
System.  
Note: For correct operation, you require LDM Configurator Software, version 9.2.2.0 when you are installing 
the Ultra 1.5 meter ABS Pedestal System to a Local Device Manager.  
To configure a LDM to the Ultra 1.5 meter ABS Pedestal System, complete the following procedure: 
1.  Connect your laptop to the RS-232 service port, J2, on the primary controller board. For the location of J2, 
2.  Launch the CE ADS4 Platform Configurator.  
3.  From the Configuration menu, select Change Network Address.  
4.  On the Enter Device’s Network Address window, in the Pack Address field, set the device address in the 
range of 1 to 253.  
5.  Click OK. 
Note: You must enter a unique address from other addresses on the network.  
For more information on connecting the Ultra 1.5 meter ABS Pedestal System to a Local Device Manger, 
see the CBC-4055 Local Device Manager II Installation Guide, 8200-0858-01.