RFID READER MODEL IDR-3000 INSTALLATION AND SERVICE GUIDE (8200-0222-02, REV. 1/A)
5 of 9
8. Verify that the settings shown are correct.
Then, click the Restart System button.
It may take several seconds for the reader to
restart. If the IP address was changed, you
must type the new address in the browser
address field to communicate with the reader.
restart. If the IP address was changed, you
must type the new address in the browser
address field to communicate with the reader.
9. Once the system restarts, the RFID reader is
ready to receive commands from the network.
10. Use the Query page of the browser-based
interface to verify antenna operation.
11. Close the browser window. Start the RFID
reader application on the network.
Service
Using the Browser-Based
Interface
The EPC/Multi-Band Reader browser-based
interface communicates directly with the RFID
reader. It includes several tools that enable you to
monitor reader performance, change reader
settings, and upgrade reader firmware.
interface communicates directly with the RFID
reader. It includes several tools that enable you to
monitor reader performance, change reader
settings, and upgrade reader firmware.
A navigation menu provides access to the
following:
following:
•
Current Operational Settings page
•
Query page
•
Radio Settings page
•
Network Settings page
•
Firmware Upgrade page
•
Startup Settings page
•
Help page
The browser-based interface can be run from any
PC on the network. However, it must be configured
with an IP address and subnet mask compatible
with the current operational settings of the reader.
PC on the network. However, it must be configured
with an IP address and subnet mask compatible
with the current operational settings of the reader.
To start the browser-based interface:
1. Exit all RFID reader applications on the
network.
IMPORTANT: Running another RFID reader
application while using the browser-based
interface may cause a reader error. If this
happens, reboot the reader or restart it using
the browser-based interface.
application while using the browser-based
interface may cause a reader error. If this
happens, reboot the reader or restart it using
the browser-based interface.
2. Start a Java-enabled web browser from any
network-enabled PC.
3. Type the IP address of the reader you want to
communicate with in the Address field of the
browser.
browser.
4. A navigation menu and the Current
Operational Settings page appear in the
browser.
browser.
Current Operational Settings Page
The Current Operational Settings page shows the
current settings of the reader. These settings are
also displayed at the bottom of the Startup Settings
page.
current settings of the reader. These settings are
also displayed at the bottom of the Startup Settings
page.
1. Click
the
Status link in the navigation menu to
display the Current Operational Settings page.
2. Close the browser window if you are finished
using the browser-based interface.
Query Page
Use the Query page to monitor reader
performance. The Query page is useful for
verifying performance when installation is complete
and for troubleshooting performance issues.
performance. The Query page is useful for
verifying performance when installation is complete
and for troubleshooting performance issues.
The Query field includes a drop-down list (at the
right of the screen) that enables you to specify the
operating mode. The operating mode specifies the
tag protocols and antenna ports to be used in
conjunction with the Query page.
right of the screen) that enables you to specify the
operating mode. The operating mode specifies the
tag protocols and antenna ports to be used in
conjunction with the Query page.
Note: The selected settings DO NOT affect reader
performance associated with other applications.
performance associated with other applications.
Navigation
menu
menu