Tyco Safety Products/Sensormatic IDR3000 Manuel D’Utilisation

Page de 9
 
RFID READER MODEL IDR-3000 INSTALLATION AND SERVICE GUIDE (8200-0222-02, REV. 1/A) 
8 of 9 
Rebooting the Reader 
Use this procedure to recover from a reader error. 
1.  Disconnect power from the reader. 
2.  Re-connect reader power. 
Wait for at least 60 seconds for the reader to 
boot up. The Power/Heartbeat LED is solid 
green while the reader boots. When the LED 
begins blinking, the boot process is complete. 
Using Safe Mode 
Use the Safe Mode button on the reader connector 
panel to recover from errors that disable the 
reader.  
Safe mode operation restores factory default 
settings as follows: 
Firmware Version:  ....... factory installed version 
UHF (915 MHz) RF Transmit Power: ..............7 
HF (13.56 MHz) RF Transmit Power:  .............7 
IP Address: .......................................10.0.0.101 
Subnet Mask:  .....................................255.0.0.0 
Gateway: ..............................................10.0.0.1 
Although the browser-based interface pages are 
displayed in red when operating in Safe mode, the 
reader is fully functional. In most cases, the reader 
will need to be reconfigured for operation with the 
reader application after starting in Safe mode. 
1.  Disconnect power from the reader.  
2.  Depress and hold the Safe Mode button while 
restoring power to the reader. Keep the Safe 
Mode button depressed until the reader boots 
completely (the green Power/Heartbeat LED 
blinks). 
 
3.  Factory-default settings are restored. 
4.  Use the browser-based interface to configure 
the reader for use with your system. 
5.  Use the Startup Settings page to restart the 
reader so the configuration changes take 
effect. Once the restart is complete, the reader 
is no longer in Safe Mode. 
Specifications 
Electrical 
RFID Reader 
UHF operating frequency ................... 902–928MHz 
HF operating frequency........................... 13.56MHz 
Input voltage......................................... 15Vdc, 3.0A 
Separate Power Supply 
Input voltage.......... Nominal 100–240Vac, 50/60Hz 
Ac line current .......................Nominal 0.5A at 120V 
Output voltage ..............  Nominal 15Vdc, 4.2A peak 
 
certified limited power source 
 Class 
Environmental 
Operating temperature: ....0° to 40°C (32° to 104°F) 
Relative humidity:............0 to 90% non-condensing 
Mechanical 
Length ...........................................26.5cm (10.4 in.) 
Width .............................................26.6cm (10.4 in.) 
Width (including mounting bracket)..30.5cm (12 in.) 
Height ................................................3.8cm (1.5 in.) 
Weight ..................................................1.4kg (3 lbs) 
Supported Tag Protocols 
915 MHz (Alien EPC) 
13.56 MHz (Philips I-Code 2, ISO 15693) 
 
Safe Mode button
Power/Heartbeat LED