Tyco Safety Products/Sensormatic IDRDR2 Manuel D’Utilisation
AGILE2 READER
8200-0222-08, REV. A
INSTALLATION AND SERVICE GUIDE
12 of 13
Although the browser-based interface pages are
displayed in red when operating in Safe mode, the
reader is fully functional. In most cases, the reader
will need to be reconfigured for operation with the
reader application after starting in Safe mode.
displayed in red when operating in Safe mode, the
reader is fully functional. In most cases, the reader
will need to be reconfigured for operation with the
reader application after starting in Safe mode.
1. Disconnect power from the reader.
2. Press and hold the Safe Mode button while
restoring power to the reader. Keep the Safe
Mode button pressed until the reader boots
completely (the green Power/Heartbeat LED
blinks).
Mode button pressed until the reader boots
completely (the green Power/Heartbeat LED
blinks).
3. Factory-default settings are restored.
4. Use the browser-based interface to configure
the reader for use with your system.
This PC must be configured with an IP address
and subnet mask compatible with the reader
default settings. For example: IP address
10.0.0.10, net mask 255.0.0.0.
and subnet mask compatible with the reader
default settings. For example: IP address
10.0.0.10, net mask 255.0.0.0.
5. Click the Settings link on the navigation menu
and verify the new settings.
6. Restart the reader with the new settings. Once
the restart is complete, the reader is no longer
in Safe Mode.
in Safe Mode.
Specifications
Electrical
Reader
UHF operating frequency....................902–928MHz
Input voltage ........................................ 24Vdc, 3.0A
Input voltage ........................................ 24Vdc, 3.0A
Separate Power Supply
Input voltage ..........Nominal 100–240Vac, 50/60Hz
Ac line current .......................Nominal 0.5A at 120V
Output voltage............... Nominal 24Vdc, 2.5A peak
Ac line current .......................Nominal 0.5A at 120V
Output voltage............... Nominal 24Vdc, 2.5A peak
Certified limited power source
Class
2
Environmental
Operating temperature:....0° to 40°C (32° to 104°F)
Relative humidity:............ 0 to 90% non-condensing
Relative humidity:............ 0 to 90% non-condensing
Mechanical
Reader — IDRDR2
Length .............................................26.5cm (10.4in)
Width...............................................26.6cm (10.4in)
Width (with mounting bracket) ...........30.5cm (12in)
Depth ..................................................3.8cm (1.5in)
Weight.................................................. 1.4kg (3 lbs)
Width...............................................26.6cm (10.4in)
Width (with mounting bracket) ...........30.5cm (12in)
Depth ..................................................3.8cm (1.5in)
Weight.................................................. 1.4kg (3 lbs)
Antenna — IDANT20TNA25
Length .........................................64.13cm (25.25in)
Width.............................................31.03cm (12.2in)
Depth ................................................4.32cm (1.7in)
Weight............................................. 1.6kg (3.45 lbs)
Width.............................................31.03cm (12.2in)
Depth ................................................4.32cm (1.7in)
Weight............................................. 1.6kg (3.45 lbs)
Antenna — IDANT21TNA25
Length .........................................73.03cm (28.75in)
Width.............................................31.03cm (12.2in)
Depth ................................................4.32cm (1.7in)
Weight............................................... 1.8kg (3.9 lbs)
Width.............................................31.03cm (12.2in)
Depth ................................................4.32cm (1.7in)
Weight............................................... 1.8kg (3.9 lbs)
Antenna — IDANT10CNA25
Length ................................................31cm (12.2in)
Width..................................................31cm (12.2in)
Depth ..................................................5.3cm (2.1in)
Weight............................................... 0.7kg (1.6 lbs)
Width..................................................31cm (12.2in)
Depth ..................................................5.3cm (2.1in)
Weight............................................... 0.7kg (1.6 lbs)
Supported Tag Protocols
915 MHz...............................................EPC Class 1
EPC Class 0
ISO
18000-6B
Safe Mode button