AMS-3000 ANTENNA INSTALLATION GUIDE (8200-0179-02, REV. 0) 
3 of 12 
Tools and Equipment Required 
For all system installations: 
• 
Plastic sheeting at least 0.15mm (6-mil) thick (to 
protect nearby items from dust) 
• 
Chalk or red permanent marker 
• 
Floor saw 
• 
PVC pipe cutter or hacksaw 
• 
Hammer drill with 6.5mm (1/4") and 9.6mm 
(3/8") masonry drill bits 
• 
Power drill with 1.6mm (1/16"), 6.5mm (1/4"), 
and 9.6mm (3/8") drill bits 
• 
Hammer 
• 
Phillips and slotted screwdrivers 
• 
14-16 AWG and 16-22 AWG wire strippers 
• 
Ratchet and socket set 
• 
Vacuum and broom 
• 
Wet vacuum 
• 
Level 
• 
Electrical tape 
• 
Teflon pipe tape 
• 
Caution tape 
• 
Duct tape 
• 
Clear lacquer spray 
Installation 
To install the AMS-3000 antenna, perform the 
following steps. 
I. 
Plan the installation. 
II. 
Perform a “tape up” to ensure system can 
be installed. 
III. 
Install the controller. 
IV. 
Dig trench, install floor conduit, and feed 
wires. 
V. 
Prepare extrusions (drill holes, cut 
extrusions, feed wires, and attach 
Rangers). 
VI. 
Attach extrusions and corner pieces 
VII. 
Mount cap box, 1x1 channel (if necessary), 
and route wires. 
VIII. 
Connect antenna and receiver wires to 
power pack and cap box. 
IX. 
Mount remote alarm and connect. 
X. 
Configure, tune, and test. 
Planning the installation 
Plan the placement of the controller, cap box, 
receivers (Rangers), and the loop. See Planning 
Guide for all details. 
Controller restraints 
• 
Determine whether the controller can be visible 
to customers. If it must be hidden it can go 
above a drop ceiling or in another room. 
• 
Ensure the ranger cables will be long enough 
to reach the controller. 
• 
Ensure the transmitter (loop) cables will be 
long enough to reach the controller. 
• 
If you have multiple loops near each other, 
resolve all antenna issues: one pack or two, 
placement of controller to reach both antennas.  
• 
Ensure the controller will be near a power 
outlet. 
Cap box restraints 
• 
Determine whether the cap box will go above 
the antenna or off to the side near the floor. 
• 
Determine if the cap box can be visible or must 
be hidden. If it must be hidden it can either go 
above a drop ceiling or be mounted in a wall 
off to the side of the antenna. 
• 
Locate a suitable mounting surface (stud 
location, grout lines). 
• 
Ensure the cap box is within 1.2m(4ft) of the 
loop. 
Ranger restraints 
• 
Ensure that the height of rangers does not 
obstruct the operation of the door. 
Loop restraints 
• 
Determine whether the extrusions will go on 
the store side of the doorframe or within the 
arch of the doorframe. 
• 
The only allowable configuration for the loop 
antenna is an “L” shape, so ensure the 
antenna can be routed in the floor in this way. 
• 
Measure the height and width of the doorframe 
to determine extrusion lengths. 
• 
Keep loops on separate packs several feet 
apart.