HM Electronics Inc XCVR2G4A Manuel D’Utilisation
User Guide | FreeSpeak II™
Page 115
9.2.1.4
Transceiver/antenna connectors
These five RJ-45 connectors are used to connect up to five remote
transceiver/antennas to the splitter, and via the splitter to the FS II Base station.
Each of these cables can be up to 1,000 meters (3,200 feet) in length if 24AWG
cable is used or up to 500 meters (1,600 feet) long if 26AWG cable is used.
transceiver/antennas to the splitter, and via the splitter to the FS II Base station.
Each of these cables can be up to 1,000 meters (3,200 feet) in length if 24AWG
cable is used or up to 500 meters (1,600 feet) long if 26AWG cable is used.
Note:
It is recommended that shielded Ethernet cable (for instance, CAT-5/5e/6) is
used.
used.
9.2.2
PD2203 rear panel
Figure 9-4 FS II Splitter Rear Connector Panel
9.2.2.1
Serial data connector
This 3.5 mm (1/8 inch) tip-ring-sleeve (TRS) connector is used for upgrading the
firmware in the PD2203. It will typically be unused.
firmware in the PD2203. It will typically be unused.
9.2.2.2
Power Indicator
This green LED indicates that the splitter is receiving power from the external
power supply.
power supply.
9.2.2.3
DC IN power connector
This connector is used to locally power the antenna splitter with the supplied
universal power supply. Use of local power is required.
universal power supply. Use of local power is required.
9.2.2.4
EXP IN connector
This male DB-15 connector is reserved for future use.