Tait International Limited TBCH1A Manuel D’Utilisation

Page de 138
 
66
Working with Base Stations from Your PC
TB9400 Installation and Operation Manual
© Tait Limited April 2014
The base station has enough space for two firmware packages. If 
the base station already has two packages, delete the unwanted 
package before downloading another.
4.4.10
Checking for Interference on a Receive Channel
You can use the Signal Level page (Diagnose > RF Interface > Signal 
Level) to look for sources of interference across a range of receive 
frequencies.
The chart on this page has two lines. One shows the current RSSI 
measurement for the selected frequency. The second shows an historical 
trace of peak RSSI readings on that frequency.