SYSTEM COMPONENTS
CellComSL
 
Series Communicator Install/Programming Guide 
Digital Monitoring Products
3
7.  Plug the battery into the BAT connector (J26).
Note: If removing the communicator from service, disconnect the system battery from the BAT connector (J26).
Battery Supervision
The communicator tests the battery once every hour when DC power is present. This test occurs 15 minutes past
each hour and lasts for five seconds. A load is placed on the battery and if the battery voltage is low, a low battery
is detected. If DC power has failed, a low battery is detected any time the battery voltage falls below 3.7 VDC.
1.3  Programming Connection (PROG J8)
A 4-pin header (PROG) is provided to connect a keypad when using a DMP Model 330
Programming Cable. This provides a quick and easy connection for programming the
CellComSL
 Series Cellular Alarm Communicator. After programming is complete, remove
the keypad.
1.4  Tamper (C3)
The tamper button is pressed when the cover of the CellComSL Series
Communicator is secured onto the enclosure. When the cover is removed, the
communicator sends a Tamper Trouble message to the Central Station.
1.5  Reset Button
The Reset button (S1) is located on the right side of the circuit board and is used
to reset the communicator microprocessor. After resetting the communicator, begin 
programming within 30 minutes. If you wait longer than 30 minutes, reset the
communicator again.
1.6  Load Button
The CellComSL Series Cellular Alarm Communicator software can be updated
via the programming (PROG) header. To update the communicator with a new software
version, complete the following steps at the protected premise:
1.  Connect a DMP 399 Cable from the Programming Header to the serial port of your
PC operating Remote Link and containing the communicator RU file.
2.  Start Remote Link and create or open the account that matches the communicator
to be updated.
3.  Set the Connection Information Type to Direct with a baud rate of 38400 and
choose the appropriate COM port.
4.  Select Panel>Remote Update, then select the correct RU file for the
communicator.
5.  Press and hold the LOAD button (S2), then press and release the RESET button.
6.  Release the LOAD button and click <Update> in Remote Link.
7.  After the software update is completed, remove the 399 cable and press the RESET button to resume normal
operation.
Figure 5: Terminals T and R 
RESET
LOAD
B
AT
MODEL CellComSL
PROG
S N
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
J8
J26
J9
S1
S2
S3
Figure 7: PROG Port Location
RESET
LOAD
B
AT
MODEL CellComSL
PROG
S N
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
J8
J26
J9
S1
S2
S3
Figure 8: Tamper (S3) Location
RESET
LOAD
B
AT
MODEL CellComSL
PROG
S N
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
J8
J26
J9
S1
S2
S3
Figure 9: Reset (S1) and 
Load (S2) Button Location