ademco 8DL5800RP2 Manuel D’Utilisation

Page de 2
LED FUNCTIONS 
PROGRAMMING NOTES 
Programming for Combined Trouble Reporting  
(Check-in, low battery†, AC loss, and RF jam messages all report on one zone.)
1. Set DIP switch 2 to OFF (keep switch 2 in the OFF position when enrolling is complete).
2. Assign the 5800RP-ADT to a zone for sending check-in, low battery†, AC loss, and RF jam messages, and enroll its serial number. When prompted, toggle
the tamper switch to enroll the serial number. The yellow LED should blink on when messages are sent.
Program the zone as follows:
Zone Type 
Input Type 
Loop 
8 (24-hour aux) 
3 (supervised RF) 
• AC loss and RF jam conditions report as “low battery” status, which is also displayed on the control’s keypads. This prevents either condition from causing
an alarm when the control is armed.
• Tamper conditions report according to the zone type response for which the trouble zone is programmed (ex. ZT 8, 24-hr Aux).
• The 5800RP-ADT will not repeat a message that has already been repeated.
Programming for Individual Trouble Reporting  
(Check-in/low battery†, AC loss, tamper, and RF jam messages report on 4 individual zones.)
1. Assign 4 zones and enroll the module’s two serial numbers as follows:
– Assign the first serial number to a zone for sending low battery† and supervision check-in messages.
– Assign the second serial number to 3 zones for sending tamper, AC loss, and RF jam messages.
When prompted, toggle the tamper switch to enroll the serial numbers. 
Program the zones as follows:
 
First Serial Number: located on PCB label. 
Set DIP switch 2 to OFF, then enroll as follows: 
Zone 
Zone Type 
Input Type 
Loop 
Low Battery/ 
Check-in Zone 
(24-hour aux) 
3 - RF 
(supervised RF) 
Second Serial Number: equals first serial number plus 1. (example: if the last 2 digits of Serial #1 are 39, Serial #2 will end with 40.) 
Set DIP switch 2 to ON, then enroll as follows: 
(keep switch 2 in the ON position when enrolling is complete) 
Zone 
Zone Type 
Input Type 
Loop 
Tamper Zone 
(trouble by day / alarm by night) 
4 - UR 
(unsupervised RF) 
AC Loss Zone 
8 (24-hour aux) 
4 - UR 
RF Jam Zone 
8 (24-hour aux) 
4 - UR 
For  easy  identification  of  these  messages,  program  alpha  descriptors  at  the  control  for  each  zone,  using  words  such  as  “REPEATER  LOW  BATTERY, 
REPEATER AC LOSS, etc. 
†  If an actual low battery condition is reported, it takes up to 24 hours after AC power is restored for the low battery restore message to be sent. 
Note  for  Control  Panel’s  Current  Drain  Calculation:  When  choosing  the  backup  battery  capacity  for  systems  using  a  5800RP-ADT,  use  the  connected 
keypad’s maximum alarm (sounder on) current rating, not the keypad’s standby current rating, when calculating the control panel’s total current drain. This is 
necessary because AC loss at the 5800RP-ADT causes the keypad to beep. 
SPECIFICATIONS 
Dimensions:  7-3/8" W x 4-3/8" (10-7/8” w/antennas) H x 2-1/8" D 
188mm W x 112mm H (277mm w/antennas) x  54mm D 
Input Voltage:12VDC or 9VAC, 15VA (from separate power supply such as Honeywell 300-07753). 
Current: 
80mA 
Battery Pack:  rechargeable, part number 300-03865 
Range: 
200ft (60m) nominal indoors from wireless devices (the actual range to be determined with the security system in the TEST mode). 
TO THE INSTALLER 
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system.  
The installer should assume the responsibility of developing and offering a regular maintenance program to the user, as well as acquainting the user with the proper operation and 
limitations  of  the  alarm  system  and  its  component  parts.  Recommendations  must  be  included  for  a  specific  program  of  frequent  testing  (at  least  weekly)  to  insure  the  system's 
operation at all times.  
FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS 
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.  Unauthorized changes or modifications 
could void the user's authority to operate the equipment. 
CLASS B DIGITAL DEVICE STATEMENT 
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: 
This  equipment  generates  and  uses  radio  frequency  energy  and  if  not  installed  and  used  properly,  that  is,  in  strict  accordance  with  the  manufacturer's  instructions,  may  cause 
interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 
15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: 
• 
If using an indoor antenna, have a quality outdoor antenna installed. 
• 
Reorient the receiving antenna until interference is reduced or eliminated.  
• 
Move the radio or television receiver away from the receiver/control. 
• 
Move the antenna leads away from any wire runs to the receiver/control. 
• 
Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. 
• 
Consult the dealer or an experienced radio/TV technician for help. 
Federal Communications Commission (FCC) Part 15 
This device complies with Part 15 of the FCC Rules and RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit 
pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. 
INDUSTRY CANADA CLASS B STATEMENT 
This Class B digital apparatus complies with Canadian ICES-003. 
Cet Appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 
 
 
 
 
 
 
Ê800-20965[Š 
ADT Security Services
1501 Yamato Rd
Boca Raton, FL 33431
Copyright © 2013
800-20965-1  9/15  Rev. 
 
LED 
Activates Upon 
Green 
Normally on (lighted) when power (AC or battery) is present. Flickering indicates RF is being processed. 
Yellow 
Normally off. Blinks to indicate that an RF message is being sent by the 5800RP. 
Red 
Normally off. Turns on (lighted) when setting Site ID. See the Setting the Site ID section for details. 
Red RF Interference 
Lights when RF activity is present. 
SUPPORT & WARRANTY 
For the latest documentation and online support information, please go to: 
https://mywebtech.honeywell.com/ 
For the latest warranty information, please go to: 
www.honeywell.com/security/hsc/resources/wa.
 
MyWebTech 
Warranty
PRELIMINARY