N. V. Nederlandsche Apparatenfabriek NEDAP ADRRFMD Manuel D’Utilisation

Page de 59
Page 
 of 
39
59
Manual iSense Lumen series
Led
Color
Status
Explanation
2
Blue
Blinking
There is 
 device connected to the OUT port of this unit
no
On
There is a Power Inserter connected to the OUT port of this unit
3
Red
On
There is an issue with the power supply at the OUT port of this unit (too little
current drawn)
Blinking
There is an issue with the power supply at the OUT port of this unit (too much
current drawn)
Off
There is 
 issue with the power supply at the OUT port of this unit
no
4
Yellow
Blinking
The operating system on the Renos unit is running
Off
The operating system on the Renos unit is 
 running
not
5
Green
Blinking
The storage flash on the Renos unit is accessed
Off
The storage flash on the Renos unit is 
 accessed
not
6
Green
On
The firmware on the Renos unit is running
Off
The firmware on the Renos unit is 
 (yet) running
not
Please refer to the Troubleshooting chapter later in this manual to resolve erroneous conditions.
Firmware error
If the Renos unit has a firmware error, the rightmost three LEDs (4, 5 and 6) will remain off when the
unit is powered. This can be solved by using a 'Local - single unit' firmware update, as is described
later on in this manual.