Mechanical installation 
6.1  Mounting platform 
MOUNTING PLATE 
The SCV/ SxV radome radar requires an 8.0mm flat aluminium 
or steel mounting plate. 
The plate should be pre-drilled to accommodate the radome 
radar, an earthing/ grounding point, any cables access holes 
and cable restraining points.  
Prior to installation, the proposed mounting plate and location 
must be inspected and accepted as being suitable. 
All four planes shown (A, B, C and D) should be checked to 
ensure the surface is flat and that there is no curvature of the 
plate. The maximum deviation should not exceed 1.0mm. 
 
 
Example of SCV and SxV mounting plate. 
Not to scale.  
See following pages for dimensions
 
 
The mounting platform and any supports (masts etc.) must be able to fully support the weight of the 
radome radar and be designed to minimise vibration. 
 
MOUNTING BARS 
The full mounting surface area of the 
SCV/ SxV chassis must be in contact 
with the mounting plate.  
 
Kelvin Hughes STRONGLY advises 
against mounting the SCV/SxV on 
brackets or mounting bars as this can 
cause twisting of the radome radar 
chassis. A flat, even surface is strongly 
recommended. 
 
      
 
Mounting brackets, bars or tubes are NOT recommended.
 
 
EARTHING/ GROUND POINT 
A tested/ proven ground point grounding/ earthing point will be required on the mounting plate or 
platform for connection to the M6 earth stud located on the base of the radome radar. See section 6.4 
(SCV) or section 6.5 (SxV) for the location of the earth stud. Kelvin Hughes Ltd recommend that the 
earth/ ground connection is always connected to the common platform chassis ground.  
 
BATTERY CONNECTION 
Portable systems powered by a battery do not require an earth connection 
 
ORIENTATION 
  The SCV/ SxV radome radar must be mounted in an upright position as shown below with the 
LAN and DC connectors pointing backwards/ aft. 
  Due to the beamwidth of the antenna, target detection will be significantly reduced if the SCV/ 
SxV assembly is tilted by more than 12.5° from horizontal/ flat.  
Please consult with Kelvin Hughes Ltd if alternative mounting positions (i.e. inverted etc.) are 
required. 
 
Forward 
Power & LAN 
connections 
Up