ActiGraph LLC 01 Manuel D’Utilisation

Page de 15
   
 
 
 
www.theactigraph.com
 
P a g e
 | 7
 
49 E. Chase St.             Pensacola, FL 32502              tel 850.332-7900             fax 850-332-7904 
Introduction 
The wGT3X+ and wActiSleep+ activity monitors provide objective measurements of human activity and 
are  used  in  many  research  and  clinical  applications.    They  include  a  microelectromechanical  system 
(MEMS) based accelerometer and an ambient light as data sensors.   
Specifications and Functionality of the wGT3X+ and wActiSleep+ 
Data 
The devices include both an acceleration sensor as well as an ambient light sensor.   
Acceleration 
The  devices include an  acceleration sensor  that  consists of a microelectromechanical systems (MEMS) 
accelerometer yielding the following product specifications: 
Parameter 
Value 
Units 
Axis 
 
Sensitivity 
220 
mV/g 
Dynamic Range 
+/- 6 
Table 1 – Accelerometer Key Specifications 
The acceleration data is sampled by a 12 bit analog to digital converter at rates ranging from 30 Hz to 
100  Hz  (user  selectable)  and  stored  in  a  raw,  non-filtered/accumulated  format  in  the  units  of  gravity 
(G’s).  This data is stored directly into a 256 or 512 MB non-volatile flash memory. 
Ambient Light 
Ambient light data is sampled and stored to memory at a 1 Hz rate.  When a downloaded data file is 
converted into an accumulated *.agd format with epoch lengths greater than one second, the lux values 
for that epoch are averaged.  An estimate of lux values is shown in Table 1. 
Lux Level 
Interpretation Comparison 
Twilight 
50 
Family living room 
100 
Very dark overcast day 
320-500 
Office lighting