General
The Somfy Z-Wave ILT Interface is a Z-Wave routing slave that resides as a node within a designated Z-Wave control
network. It receives Z-Wave transmissions and coverts them to motor control commands for Somfy’s Sonesse 50
ILT2 (AC) motor and Sonesse 30 RS485 (DC) motor. These motors will provide feedback on present position to the
interface which in turn is available to the Z-Wave network.
One interface is used for each Sonesse 50 ILT2 and Sonesse 30 RS485 motor.
The interface is mounted within thirty (30) feet of each motor head.
The interface is compatible with all automation, handheld and PC based controls using the Z-Wave 300 series chip.
Zensys Z-Wave certified.
network. It receives Z-Wave transmissions and coverts them to motor control commands for Somfy’s Sonesse 50
ILT2 (AC) motor and Sonesse 30 RS485 (DC) motor. These motors will provide feedback on present position to the
interface which in turn is available to the Z-Wave network.
One interface is used for each Sonesse 50 ILT2 and Sonesse 30 RS485 motor.
The interface is mounted within thirty (30) feet of each motor head.
The interface is compatible with all automation, handheld and PC based controls using the Z-Wave 300 series chip.
Zensys Z-Wave certified.
Initial Interface Set Up
Before programming the Interface, the motorized window covering should be installed and motor limits set.
1. Inclusion LED will illuminate for five (5) seconds when power is first plugged in.
2. Press SETUP button once to verify motor movement. Motor movement with inclusion LED OFF indicates that
the interface is ready to be included in an existing Z-Wave network.
3. Select the inclusion command on your Z-Wave programmer / remote controller.
4. Press the interface SETUP button once to include it in the network.
4. Press the interface SETUP button once to include it in the network.
Connection to ILT motor.
Powered provided by motor
for interface.
Powered provided by motor
for interface.
24 V DC in for Sonesse 30
Powers Interface
Powers Interface
24 V DC out for Sonesse 30
Data for Sonessse 30
Programming button for Z-WAVE
“Part of Z-WAVE Network” LED