International Business Machines Corporation 35H3636 Manuel D’Utilisation

Page de 123
Open Error Codes
If the open provides a return code of 7, there will be a corresponding error code.
The open errors are returned in 2 bytes. The high-order byte is always 0 and the
low-order byte contains the following information:
1. The phase of testing in which the error was encountered is in the high-order
nibble (half-byte) of the low-order byte.
2. The error condition is in the low order nibble of the low-order byte.
Phases
Value
Meaning
1n
Lobe media test
2n
Physical insertion
3n
Address verification
4n
Roll call poll (neighbor notification)
5n
Request parameters
Errors
Value
Meaning
n1
Function failure
n2
Signal loss
n3
Reserved
n4
Frequency error (see note)
n5
Time-out
n6
Ring failure
n7
Ring beaconing
n8
Duplicate node address
n9
Parameter request—retry count exceeded
nA
Remove received
nB
IMPL force received
nC
Duplicate modifier
nD
No monitor detected
nE
Monitor contention failed for RPL
Suggested Actions in Response to Open Errors
When the following phase-error combination values are presented, they are the
result of certain specific occurrences. Explanation of the occurrences follows with
recommended actions listed. Table 8 on page 86 lists the recommended actions for
both the application program and the computer operator.
Error Code
Explanation
Action
11
Lobe Media, Function Failure: The testing of the lobe
between the PC Card and the access unit has been
unsuccessful because the lobe has a bit-error rate
that is too high, or the PC Card cannot receive
successfully.
1, 3, and 5
Appendix C. Running the Diagnostics Program
83