RELM Communications Inc RPU499A Manuel D’Utilisation

Page de 29
 
30 
 
12 480  √ 
√ 
 
√ 
√  
45.05 
480 
470 
490 
 
13 490  √ 
√ 
√ 
√ 
√  
46.35 
490 
480 
500 
 
14 360  √ 
 
 
 
√  
46.35 
360 
350 
370 
 
15 380  √ 
 
 
 
√  
45.05 
380 
370 
390 
 
 
 
Note: About busy channel lockout 
*
1: Transmission is prohibited if a signal appears with incompatible CTCSS/CDCSS;     
*
2: Transmission is prohibited if a signal appears with incompatible CTCSS/CDCSS or DTMF/2-Tone. 
 
ALL RESET MODE 
Operation 
1.  Turn POWER ON while pressing [LAMP] and [
] key, in about 2 seconds, the radio enters the Dealer   Mode.  
2.  In dealer mode, press [PTT] and [
] key simultaneously to enter All Reset Mode. The EEPROM data is reset. No 
change displays on LCD, and red LED glows. 
3.  The LED turns off when All Reset is completed. 
 
 
 
 
 
 
PC MODE 
Connection procedures 
1. Connect the radio of RPV599APlus/RPU499APlus to the personal computer with an interface cable. 
2. Run the program on the computer and Turn ON the power of the radio.  
3. You can read, programme or adjust the radio via RPV599APlus/RPU499APlus programming software. 
 
Please refer to “RPV599APlus/RPU499APlus Editing Software User Manual” for details. 
 
 
 
 
Red LED on
Red LED off  
All Reset Complete
All Reset
Dealer Mode
[PTT]+[LO]
[PTT]+[