Antenna cable grounding and optional surge suppression
Overview
The following paragraphs specify the requirements for grounding of the RF antenna
cables and the addition of optional surge suppression. For more information on antenna
grounding, refer to Grounding and Lightning Protection Guidelines for Alcatel-Lucent
Network Wireless System Cell Sites, 
401-200-115.
The following diagram shows a typical method for connecting an antenna jumper cable.
Optional surge suppression requirements
The RF path of the Alcatel-Lucent B25 RRH4x30 is equipped with an internal surge
protector; external surge suppression is optional and may be installed between each
antenna coaxial cable and jumper cable. They can be obtained from Alcatel-Lucent
(KS24577, L-9A for RF), or an Alcatel-Lucent-approved equivalent can be used. The
surge protectors must be bonded to a nearby ground bus bar that is connected directly to
the grounding electrode system.
Important! All surge protectors must be at least IP67 rated. (IP67 rating requirement,
as defined by IEC 60529, calls for total protection against dust and protection against
submersion in water.)
DOUBLE HOLE LUG
TO BUS BAR
#6 AWG STRANDED INSULATED
COPPER GROUND WIRE
ANTENNA CABLE
CABLE GROUND KIT
Antenna interface
Antenna cable grounding and optional surge suppression
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-4
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
B25 RRH4x30
3MN-02023-0001-RJZZA
Issue 0.02
January 2015