HARRIS CORPORATION KRC121109-1 Manuel D’Utilisation

Page de 59
System Description
Table 3-4.
Macro with MCPA, 1900 MHz Technical Specifications (Continued)
Temperature
-25 C to +60 C
Temperature change
0.5 C/min
Relative humidity
5-95%
Absolute humidity
29 g/m³
Climatic conditions during
storage
Time
12 months
+5 C to +40 C
Temperature
(TMA -33 C to +55 C)
Temperature change
0.5 C/min and
10 C/h
Relative humidity
15 – 80%
Climatic conditions during
normal operation
Absolute humidity
1 – 20 g/m³
Sinusoidal vibration
20 m/s² 10 – 150 Hz
Random vibration (ASD)
2 m²/s³ 5 – 150 Hz
Mechanical shock
200 m/s² <11 ms
Mechanical conditions
during transport and
storage
Air pressure
60 — 108 kPa (60 kPa corresponds to an
altitude of 4500 m)
Sinusoidal vibration
5 m/s² 10-150 Hz
Random vibration (ASD)
0.5 m²/s³ 5-150 Hz
Seismic exposure (safe
function)
35 s 1 – 15 Hz (According to IEC 68-2-57)
Mechanical conditions
during normal operation
Air pressure
60 – 108 kPa (60 kPa corresponds to an
altitude of 4500 m)
EMC
Radiated emission 30 MHz
- 1 GHz
Class B digital device (According to FCC Part
15)
Radiated emission 30 MHz
- 1 GHz
-13 dBm (transmitter) (According to FCC Part
22)
Conducted emission DC
Supply
120 Hz - 100 MHz: According to Bellcore 3.2.4
Electromagnetic Emission
Conducted emission
Telecommunication Lines
120 Hz – 100 MHz: According to Bellcore 3.2.4
Radio frequency field 80
MHz - 1 GHz except RX
band ±5%
10 V/m (According to IEC 1000-4-3)
Electromagnetic immunity,
Enclosure
ESD
8 kV contact discharge (According to Bellcore
2.2 and 2.4, and IEC 1000-4-2 level 4)
2/1551-AE/LZB 119 4239 Uae Rev A 2001-03-15
3-39