UltraSync BLUE Slave not Connecting to Master
If your UltraSync BLUE is not receiving timecode from a master
device, it could be due to:
l
The master device being switched off. Make sure the master
device is on and has sufficient battery power.
l
UltraSync BLUE is set to Int Master RF TX mode. The UltraSync
BLUE can only connect with a master device if the UltraSync
BLUE is running in RF Slave mode (see
).
l
The master is out of range. The UltraSync BLUE will use its own
timecode settings until a master is back in range.
l
The UltraSync BLUE is not set to use the same RF Channel as
the master (see
).
l
The UltraSync BLUE and/or the master are not set to the correct
country/area. You need to set the UltraSync BLUE and master to
the country/area in which they are being used (see
).
Slave is Connecting to the Wrong Master
If your UltraSync BLUE is running in slave mode and connects to the
wrong master device, it is likely that there are multiple masters in the
same RF network. An RF network should only have one master
device (one master using the specific RF channel for the network (see
).