Ericsson Radio Systems AB CKRC1311004-2 Manuel D’Utilisation

Page de 29
RBS 2107
Table 6
Maximum Power to Antenna for Various RBS 2107 Configurations
Configuration
Frequency
(MHz)
Nominal Output
Power per TRU
(dBm)/(W)
Maximum Power
into Antenna
(1)
(dBm)/(W)
900
45.2 / 33
47.2 / 53
3×2 no hybrid
1800
44 / 25
46 / 40
900
41.7 / 15
43.7 / 23
3×2 combined
1800
40.5 / 11
42.5 / 18
900
47.7 / 59
46.7 / 47
3×1 TCC
1800
46.5 / 45
45.5 / 35
(1) Including power tolerance level (+2 dB) and transmission losses (-3 dB).
4.4
Materials
All Ericsson products fulfil legal, market, and Ericsson requirements regarding:
Fire resistance of material, components, wires and cables
Declaration of materials
Use of restricted materials
Recycling
Packaging Material
The packaging materials are recyclable.
5
Hardware Units
A high level of availability is achieved using strict functional modularity in a
system of standardised Replaceable Units (RU). A failed RU can easily be
replaced by a new one.
11 (28)
EN/LZT 720 0491 Uen R2A