Ericsson Radio Systems AB KRC16131 Manuel D’Utilisation

Page de 307
Environmental Capabilities
Mechanical conditions
The mechanical conditions conform to
IEC 721-3-4 class /4M5/
ETS 300 019-1-4 class 4.1
In addition to this, Ericsson demands more rigorous values than stated
by IEC and ETSI above.
Table 79
Mechanical conditions during operation outdoor
Environmental parameter
Value
Vibration sinusoidal
displacement, mm
3.0
acceleration, m/s
2
10
frequency, Hz
2 - 9
9 - 200
Vibration random
ASD
(1)
, m
2
/s
3
0.5
frequency, Hz
2 - 200
Duration of exposure, min
30
no. of test directions
3
Shock
peak acceleration, <100 kg
m/s
2
250
peak acceleration, >100 kg
m/s
2
100
(2)
duration, ms
6
(1) ASD = Acceleration Spectral Density
(2) The requirement belongs to safe function with the following exception:
Performance of the RBS shall be verified as "no loss of calls".
Seismic exposure
Table 80
Safe function during seismic exposure
Testing severity
Frequency range
1-15 Hz
Required Response Spectrum
RRS (Required Response Spectrum)
Shape of RRS
as IEC 68-2-57 fig. 3
EN/LZT 123 2697
R5A
1998-08-13
283 (306)
© Ericsson Radio Systems AB
— All Rights Reserved —