Handling of Auxiliary Equipment
50
Handling of Auxiliary Equipment
A number of customer defined, antenna related auxiliary equipment can
be supervised by the RBS. The raising of an auxiliary fault is, after
analysis in the RBS, reported to the BSC. Depending on what severity
the operator has defined for the fault, the concerned MO could be taken
out of operation.
50.1
References
Whenever a reference is made to a function described in another chapter,
please refer to the table of contents to find the appropriate chapter.
50.2
Concepts
Auxiliary Equipment
Equipment connected to the RBS but
normally situated outside the RBS cabinet.
ARAE
Antenna Related Auxiliary Equipment.
Examples are boosters and active antennas.
Auxiliary Faults
Detected by supervision of auxiliary
equipment.
External Alarms
Binary alarms that are reported over Abis
transparently through the RBS. An
example is fire alarm.
Alarm Inlet
The binary inlet to which the supervised
equipment is connected. Used for both
Auxiliary Faults and External Alarms.
Alarm Setup
The parameter definition for the alarm
inlets, which is set by OMT.
50.3
Function
The following ARAE supervision parameters are associated with each
auxiliary fault:
Inlet number
1–16. Defines which inlet the Auxiliary
Equipment is connected to.
Inlet usage
"Auxiliary Fault", "External Alarm" or
"Not defined". The default alarm setup is
that all alarm inlets are ’Not Defined’,
which means that they have no effect on
fault reports for auxiliary equipment,
external alarms or fault indicators.
Fault activation criteria
Either closing or breaking the sensor loop.
If inlet usage is set as "Auxiliary Fault", the following fault information
parameters are also set:
Affected functionality
RX and/or TX
EN/LZT 720 0008
P2A
2001-11-28
397 (485)
© Ericsson Radio Systems AB
— All Rights Reserved —