Andrew Wireless Innovations Group M17P26 Manuel D’Utilisation
2. FUNCTIONAL DESCRIPTION
2.1.
PURPOSE
Cellular telephone systems transmit signals in two directions between base
transceiver station (BTS) and mobile stations (MS) within the signal coverage area.
If weak signal transmissions occur within the coverage area because of indoor
applications, topological conditions or distance from the transmitter, extension of the
transmission range can be achieved by means of an optical distribution system.
Such a system contains an optical Master Unit and several Remote Units. The
number of the Remote Units depends on the hardware and software configuration.
The Remote Units are connected to the Master Unit with optical links. The optical
loss must be less than 10 dB inclusive optical couplers or splitters.
The Master Unit is the connection to the base transceiver stations. The configuration
of a Master Unit depends on the number of the Remote Units and the frequency
range.
WDM (Wave Division Multiplex) filters are integrated in the optical modules. For the
UL, a wavelength within 1540 nm – 1562 nm is used. For the DL, a wavelength of
1310 ±20 nm is used. The maximum output power for the UL and DL is 5.7 mW.
2.2.
THE ION-M17P/26 EU
The
ION-M17P/26 EU
(Intelligent Optical Network; MMR)
is a high-power dual-band
Extension Unit (EU). It is used in conjunction with a Master Unit
and a Main Unit
containing the optical transceiver (OTRx)
in the ION-M optical distribution system.
This system is able to transport the whole AWS 1700 MHz band wide
simultaneously, providing a cost-effective solution for distributing capacity from one
or more base stations. Optionally, for 2600 MHz WiMAX in TDD * mode is available.
The ION-M17P/26 EU is connected via extension cable bridge to the Main Unit with
extension port. For a frequency band extension, the additional band (for ION-M17P
EU this is AWS) has just to be combined with the signal for the (Main) Remote Unit.
Then, the additional band is available on the extension port of the Main Unit.
simultaneously, providing a cost-effective solution for distributing capacity from one
or more base stations. Optionally, for 2600 MHz WiMAX in TDD * mode is available.
The ION-M17P/26 EU is connected via extension cable bridge to the Main Unit with
extension port. For a frequency band extension, the additional band (for ION-M17P
EU this is AWS) has just to be combined with the signal for the (Main) Remote Unit.
Then, the additional band is available on the extension port of the Main Unit.
The ION-M17P/26 EU transports signals on the RF layer in a very inexpensive
manner. This means that services from various operators can be transmitted
simultaneously from a cluster of base stations to a remote location over the same
fibre.
manner. This means that services from various operators can be transmitted
simultaneously from a cluster of base stations to a remote location over the same
fibre.
Any service or frequency band extension is achieved by adding an Extension Unit
(EU) without any impact to the installed network.
*
TDD is the abbrev. of time-division-duplex