Andrew Wireless Innovations Group RPT-MR803P-TR Manuel D’Utilisation
U
SER
´
S MANUAL FOR BAND SELECTIVE REPEATERS
MR
X
03P
User'sManual.doc
Id.-No.:154999
Page 32
22-Jan-01
5.3.
DIP-SWITCHES
The configuration of the DIP-switches on the control module is factory set.
figure 5-2 Control module – Position of the DIP-switches
Mode-switch [1]*
Ext. Alarms-switch [4]
ON
OFF
ON
OFF
1
Manual
Auto
1
Ext. Alarm 4
PSTN (d)
2
Remote Mode
Local Mode
2
Ext. Alarm 3
PSTN (c)
3
DO NOT USE!
DO NOT USE!
3
Ext. Alarm 2
PSTN (b)
4
DO NOT USE!
Auto
4
Ext. Alarm 1
PSTN (a)
Switch for additional inputs [2]**
MOR/MR-switch [3]
ON
OFF
ON
OFF
1
VCC
O.C.
1
MR
MOR
2
VCC
O.C.
2
MR
MOR
3
VCC
O.C.
3
MR
MOR
4
VCC
O.C.
4
MR
MOR
5
VCC
O.C.
5
MOR
MR
6
VCC
O.C.
6
MOR
MR
7
VCC
O.C.
7
MOR
MR
8
VCC
O.C.
8
MOR
MR
*
Switch 1, 3 and 4 are factory set to position Off
**
Switch for additional inputs not in use!
table 5-2 DIP-switches of control module
1
2
3
4