2  Installation 
2.1  Safety Precautions 
•  Installation, operation, and maintenance of the  Kona Macro Gateway  must only be 
performed by a professionally  trained  service  technician who is  aware of all hazards 
involved. 
•  The Kona Macro Gateway must be installed in a restricted access location (such that 
touching of the Gateway by non-service persons is not likely). 
•  The Kona Macro Gateway may become hot to the touch during normal operation at 
elevated ambient temperatures. The surface temperature of the Gateway may reach 90°C. 
•  The Kona Macro Gateway has no internal field serviceable parts. The Gateway module must 
only be opened by an approved TEKTELIC service center. 
•  All installation practices must be in accordance with the local and national electrical codes. 
•  Do not work on the system during periods of lightning activity. 
•  The Kona Macro Gateway is considered permanently connected equipment. The Protective 
Earth Ground connection (that is, the two-hole lug to chassis ground) is always required. 
•  Ensure the Kona Macro Gateway Protective Earth Ground connection is properly terminated 
prior to the connection of any other interfaces. 
•  The Kona Macro Gateway contains primary lightning surge suppression on the Direct DC 
power port, the Copper Ethernet port, the GPS antenna port and the LoRa RF antenna 
ports. The primary lightning protectors have the ability to bridge the interface isolation 
boundary  during  over-voltages.  Ensure that the Protective Earth Ground connection is 
always in place. 
•  Ensure that the Kona Macro Gateway, its antennas and supporting structures are properly 
secured  to eliminate any physical hazard to people or property.  The  Gateway  must be 
securely mounted according to the mounting instructions prior to any cable connection and 
operation. 
•  The Kona Macro Gateway does not contain a power supply disconnection device; a readily 
accessible disconnection device must be incorporated external to the Kona Macro Gateway. 
•  The direct DC powered Kona Macro Gateway shall be supplied through an input overcurrent 
protection device rated not  more  than  10  A. The overcurrent protection must have the 
appropriate current interrupt capacity for the power source and must be incorporated into 
the non-earthed conductor(s) of the Kona Macro Gateway DC supply.