Figure 10: TTU Module Mounting with One Small and One Antenna Bracket 
 
2.6  Ground Cable Installation 
The  Pearl  Gateway  is  considered Permanently Connected Equipment and requires  a 
permanently connected Protective Earth Ground (PEG) conductor  for each module. The 
Protective Earth Ground connection is made through a #8-32 screw using an industry standard 
single-hole lug as illustrated in Figure 6 for the Mobile Gateway Module, Figure 6 for the Fixed 
Gateway Module, and Figure 6 for the TTU Module. 
The recommended ground cable gauge is #10 AWG minimum. 
The  Pearl  Gateway grounding system shall follow local and national electrical codes. The 
Protective Earth Ground conductor terminated at the ground lug point is mandatory and must 
M8 screw or bolt 
4 places
 
Slot for pole strap 
4 places