2  Installation 
2.1  Safety Precautions 
•  Installation, operation, and maintenance of the Pearl Gateway must only be performed by a 
trained person who is aware of all hazards involved. 
•  The Pearl Gateway must be installed in a restricted access location (such that touching of 
the Gateway by untrained persons is not likely). 
•  The  Pearl  Gateway may become hot to the touch during normal operation at elevated 
ambient temperatures. The surface temperature of the enclosure may reach 90°C. 
•  The Pearl Gateway has no internal field serviceable parts. The Gateway module must only 
be opened by an approved service center. 
•  All installation practices must be in accordance with local and national electrical codes. 
•  Do not work on the system during periods of lightning activity. 
•  The Pearl Gateway is considered permanently connected equipment. The Protective Earth 
Ground connection to chassis is always required. 
•  Ensure the Pearl Gateway Protective Earth Ground connection is properly terminated prior 
to the connection of any other interfaces. 
•  The Pearl Gateway TTU contains primary lightning surge suppression on the RF ports. The 
primary lightning protectors have the ability to shunt lightning energy to earth ground 
which includes the chassis. Ensure that the Protective Earth Ground connection is always in 
place. 
•  Ensure that the Pearl Gateway including the TTU and its antennas and supporting structures 
are properly secured to eliminate any physical hazard to people or property. The Gateway 
including the TTU must be securely mounted according to the mounting instructions prior to 
any cable connection and operation. 
•  The  Pearl  Gateway  does not contain a power  supply disconnection device; a readily 
accessible disconnection device must be incorporated external to the Gateway. 
•  The Pearl Gateway shall be supplied through an input overcurrent protection device rated 
not  more  than  20  A. The overcurrent protection must have the appropriate current 
interrupt capacity for the power source and must be incorporated into the non-earthed 
conductor(s) of the DC supply.