Figure 13: Pearl TTU Module Ground Point 
 
2.7  DC Power Cable Installation 
The Gateway Module DC power input is isolated from chassis (earth). One lead of the DC power 
feed is normally earth referenced external to the Pearl Gateway, usually at the power source by 
convention. 
An input overcurrent protection device rated not more than 20 A, and with  the appropriate 
current interrupt capacity for the power source, must be incorporated into the non-earthed 
conductor(s) of the DC supply. 
DC power is supplied to the Mobile Gateway Module through a two pin circular plastic 
connector (CPC). The mating CPC connector shall be as specified in Table 1-2 and shall follow 
the polarity identified in Figure 14. 