4.2.20 Read Counter (0x14)
Table 4.21
The Read Counter command takes as arguments the tag Counter Number and the Data Buffer Offset in bytes. This
command reads the counter value of the counter pointed to by the Counter Number and stores it in the Data Buffer
at the Data Buffer Offset index as an unsigned 24-bit integer with the least significant byte first.
command reads the counter value of the counter pointed to by the Counter Number and stores it in the Data Buffer
at the Data Buffer Offset index as an unsigned 24-bit integer with the least significant byte first.
Command Number
Command Name
Valid Tag Types
Argument Offset [bytes]
0x00
0x01
Argument Name
Counter Number
Data Buffer Offset
Argument Size [bytes]
0x01
0x01
Argument Description
Counter number
cannot exceed number
of counters in the tag.
Buffer offset in bytes
from where the
counter value is to be
stored. Total counter
value size and the
offset cannot exceed
the data buffer length.
0x14
Read Counter
Ultralight EV1, NTAG213, NTAG215, NTAG216,
NTAG213F, NTAG216F