10. BAND EDGE EMISSION
10.1. MEASUREMENT PROCEDURE
1. The EUT operates at hopping-off test mode. The lowest or highest channels are tested to verify the largest
transmission and spurious emissions power at the continuous transmission mode.
2. Max hold the trace of the setup1, and the EUT operates at hopping-on test mode to verify the largest
spurious emissions power.
3. Set the spectrum analyzer in the following setting in order to capture the lower and upper band-edges of the
emission.
Start frequency(MHz)
Stop frequency(MHz)
2200
2405
2478
2500