SiteTel Sweden AB UNT0070-ACEGW Manuel D’Utilisation
Doc. No:
INS-0146, Rev B
Page 4 of 4
4.1
M
ECHANICAL MOUNTING
The NorthStar ACE
®
Gateway must be
installed within Bluetooth range of the
NorthStar ACE
NorthStar ACE
®
batteries.
The NorthStar ACE
®
Gateway snaps on
a DIN rail.
4.2
C
ONNECTING POWER
Remove the screws in the front of the
NorthStar ACE
NorthStar ACE
®
Gateway (see picture).
Use a sharp knife or a nipper to cut out
recesses for the cables, before tighten
the screws after connecting the power.
recesses for the cables, before tighten
the screws after connecting the power.
The DC input must be protected by a 1A fuse
4.3
CONFIGURATION
OF
THE
N
ORTH
S
TAR
ACE
®
GATEWAY
The NorthStar ACE
®
Gateway is configured via the NorthStar ACE
®
Site
Smartphone app, available for most Android and Apple devices.
For more detailed information,
DC input Voltage
42-56VDC
Power consumption
0.27A/15W
Operating temperature
-40°C to +70°C (+55°C with modem)
Installation requirements
Weather protected
IP class