MANN HUMMEL FILTER TECHNOLOGY S.E.A. PTE. LTD. SZT-1 Manuel D’Utilisation
Wiring Instructions
Do not connect directly to positive
battery source. Senzit Monitoring
Device is equipped with a GPS unit
and a cellular antenna. Direct
connection to positive battery
source will result in continuous
power to Senzit Monitoring Device
and battery depletion.
It is recommended that an in-line
fuse (5 Amp) be installed.
1. Disconnect the ground cable from the
battery.
2. Connect the red lead to a 12 Volt or 24
Volt switched ignition power source
a. Ensure a solid connect is made
b. Do not wire directly into battery source.
3. Connect the black lead to ground.
a. Ground should be unpainted surface to
ensure solid connection
4. Reconnect the ground cable to the battery.
5. Turn key to start/accessory position to
5. Turn key to start/accessory position to
power ON device.
a. Green LED indicator will illuminated in a
solid state to indicated device is
powered on.
Ignition Power
Senzit
Monitoring
Device
Red Positive (+)
Black Negative (-) to Ground