500ms
(F0205)
1000ms
(F0210)
Disable repeat read(F0100)
*Enable repeat read (F0101)
Mul ple read(F0102)
Mul ple read: The same label can only be decoded again a er
the label has not been detected for a number of
scans. This mode can only be programmed in
Con nuous read trigger mode.
the label has not been detected for a number of
scans. This mode can only be programmed in
Con nuous read trigger mode.
Disable
auto trigger(H0000)
* Enable auto trigger(H0001)
Light
LED Status
Descrip on
Scanner
Green
light on Power on/ Working normally
Red light blinks
Pairing match
Green light
blinks once Upload successfully
Green light
blinks twice Upload failed
Red
light on Low ba ery
Blue light on
Charging normal
Green light on
Charging complete
Green light blinking
Pairing unsuccessful
Red
light on USB iden fy failed
Green light blinks
once
Green
light on Working normally
Uploaded successfully
Cradle
Green light blinks 30s
Pairing state
Scan the bar code of “Enter se ng”
Enter Se ng
Scan the func on bar codes
Scan the bar code of “Exit and Save”
Exit and Save
Se ng Step
1
2
3
③ Dalay for repeating to
read the same barcode
② Reading Mode
④ Auto trigger(optional)
Set up process:
❶Scan the bar code of“Enter Setting”.
❷Scan the bar code of "Custom Suffix".
❸Scan one of bar code below as suffix
❹Scan the bar code of “Exit and Save”.
Enter Se ng
Custom Suffix
Exit and Save
None
*0x0D
(CR)
0x0A
(LF)
TAB
③ Suffix
②Numeric Keypad
Enable Numeric Keypad
*Disable Numeric Keypad
Configura on method: Scan the func on bar code directly.
Single decode
: When a bar code has been decoded, the reader will
be turned off. The reader must be triggered again to read another
label.
label.
Con nuous decode
: The reader will produce as much data as it
can decode regardless whether it is the same or not. This mode is
mainly used for demonstra on and diagnosis.
mainly used for demonstra on and diagnosis.
① Trigger Mode
*Single Read
Con nuous Read
❷Scan one of the bar code below as sleep me.
Sleep Time
60s
5min
30min
20S
3min
15min
None sleep
❸Scan the bar code of “Exit and Save”.
The sleep me means the me between the last opera on move and
auto turn off the scanner. User able to scan the corresponding bar code
of the sleep me which is needed to accomplish the sleep me se ng.
auto turn off the scanner. User able to scan the corresponding bar code
of the sleep me which is needed to accomplish the sleep me se ng.
④Sleep Time Setting
Set up process:
❶Scan the bar code of“Sleep Time”.
This part is valid for wireless se ngs only
Enter Se ng
Exit and Save
Set up process:
❶Scan the bar code of“Enter Setting”.
❷Scan the bar code of “Restore Defaults”.
Restore Defaults
❸Scan the bar code of "Exit and Save".
The default se ng allows the scanner to be restored
to the factory se ng state.
to the factory se ng state.
①Defaults Parameter
Exit and Save
Decode
Settings
Wierless
Settings
This part is valid for decode se ngs only
2000ms
(F0220)
FCC STATEMENT :
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
Warning:
Changes or modifications not expressly
approved by the party responsible for compliance could
void the user's authority to operate the equipment.
void the user's authority to operate the equipment.
NOTE:
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.