Page 39 of 64 
Region Code
1
 
Frequency 
AP 
SM 
Center Channel 
Frequencies Available
(MHz) 
consistent with your country’s regulatory requirements. 
2.  In some countries and regions, 5600 MHz to 5650 MHz is “notched” out to meet 
requirements to not transmit in weather radar frequencies. 
3.  FCC/IC indicates compliance with FCC Report and Order 03-287 and Industry 
Canada requirements. 
4.  ETSI DFS indicates compliance with ETSI EN 301 893 v1.3.1 
5.  ETSI DFS indicates compliance with ETSI EN 302 502 v1.2.1 2008 
 
After an AP or BHM with DFS boots it performs a channel availability check on its main carrier 
frequency for 1 minute, monitoring for the radar signature without transmitting. If no radar 
signature is detected during this minute, the module then proceeds to normal beacon transmit 
mode. If it does detect a radar signature, the frequency is marked for a 30 minute non-occupancy 
period, and the module moves to its 1
st
 alternate carrier frequency. The AP/BHM continues this 
behavior through its 2nd alternate frequency if needed and then waits until the first frequency 
ends the 30 minute non-occupancy period.  While operating, if the AP/BHM detects a weather 
radar signature it marks the current carrier frequency for a 30 minute non-occupancy period and 
moves to check the next-in-line carrier frequency. 
An SM/BHS does not begin transmission until it detects a beacon from an AP/BHM. If APs/BHMs 
are not transmitting, SMs/BHSs will be silent. 
The FCC and IC require DFS only on APs/BHMs. Europe applies the ETSI specification to both 
APs/BHMs and SMs/BHSs, while Brazil applies it only to AP/BHMs. In the ETSI case, when an 
SM/BHS boots, it scans to find a Canopy beacon from a AP/BHM. If an AP/BHM is found, the 
SM/BHS performs a channel availability check on that frequency for 1 minute, monitoring for the 
radar signature, without transmitting. A DFS decision is made based on the following: 
•  If no radar pulse is detected during this 1 minute, the SM/BHS proceeds through 
normal steps to register to an AP/BHM. 
•  If the SM/BHS does detect radar, it locks out that frequency for 30 minutes and 
continues scanning other frequencies in its scan list. 
Note, after an SM with DFS has seen a radar signature on a frequency and locked out that 
frequency, it may connect to a different AP if color codes, AP transmitting frequencies, and SM 
scanned frequencies support that connection. 
BHSs would not be expected to connect to a different BHM, as backhaul links should be 
configured using color codes and authentication to ensure a BHS only connects with its intended 
BHM. 
To simplify operation and ensure compliance, an SM/BHS takes on the DFS type of the AP/BHM 
to which it registers. For example, when an SM in Europe registers to an AP with the Region 
Code set to “Europe”, that SM will use ETSI DFS, no matter what its Region Code is set to, even 
if its Region Code is set to “None”. Note, the operator should still configure the Region Code in 
the SM correctly, as future releases may use the Region Code for additional region-specific 
options.