Arris WA840G Manuel D’Utilisation

Page de 70
SECTION 1 
OVERVIEW
 
1-10 SECTION 
1, 
OVERVIEW 
 
 
LED Description 
The underlined items represent network activity. 
 
    LED 
Condition 
Color 
Status 
1  Power 
ON 
Green 
The device is powered on and operating normally. 
 Blinking 
Green 
Firmware update is in progress. 
 Blinking/ON 
Red 
The power LED turns RED as soon as the reset 
button is depressed. If the reset button is held down 
for more than 5 seconds, the LED starts to blink 
during which the access point’s default user name, 
password and IP address will be restored. The LED 
then turns OFF until the reset button is released. The 
power LED keeps blinking RED if the firmware is 
corrupted indicating the firmware needs to be 
restored. 
2  Wireless  OFF 
None 
No mobile station or AP has associated with this 
device. 
 ON 
Red 
The wireless interface has been disabled by the 
firmware. 
 ON/Blinking 
Green 
802.11b/802.11g connection exists in this wireless 
domain/active traffic present. 
3  Device 
OFF 
None 
No external Ethernet device has been attached and 
detected. The Ethernet link is down. 
 ON/Blinking 
Amber
10BaseT link detected/active traffic present. 
 ON/Blinking 
Green 
100BaseT link detected/active traffic present.