ICOM 269900 Manuel D’Utilisation

Page de 88
59
10
SET MODE
D
CI-V address
To distinguish equipment, each CI-V transceiver/receiver has
its own Icom standard address in hexadecimal code. The IC-
R20’s address is “6C.’
When 2 or more IC-R20s are connected to an optional CT-17
CI
-
V LEVEL CONVERTOR
, set a different address for each IC-
R20 in the range “01” to “7F.”
(default: 6C)
D
CI-V boud rate
Sets the data transfer rate. When “AUTO” is selected, baud
rate is automatically set according to the connected controller
or other Icom CI-V radio.
(default: AUTO)
D
CI-V transceive
CI-V transceive operation is possible with the IC-R20 con-
nected to an Icom CI-V radio. When “ON” is selected, chang-
ing the frequency, operating mode, etc. on the IC-R20
automatically changes those of connected radios and vice
versa.
(default: ON)
CI-V
-
TRANSCEIVE
CI-V
-
TRANSCEIVE
-
ON
>OFF
----------------
>ON
-
OFF
----------------
CI-V transceive OFF
CI-V transceive ON
CI-V
-
BAUD
-
RATE
-
1200bps
-
300bps
-
9600bps
-
4800bps
-
19200bps
>AUTO
-
1200bps
-
300bps
>9600bps
-
4800bps
-
19200bps
-
AUTO
----------------
CI-V
-
BAUD
-
RATE
----------------
“AUTO” baud rate setting
9600 bps setting
CI-V
-
ADDRESS
-
6C
----------------
CI-V
-
ADDRESS
-
01
----------------
CI-V address set to 6C
CI-V address set to 01