Aaron & Andrew Design Inc YKQ05 Manuel D’Utilisation
4、8 hours position: The light sensor resets first and send out an OFF signal to turn off
receiver. If the environment lux level is less than 15lux, the Sensor will send out a signal to turn
on the receiver. After 8 hours, it will send out a signal to turn off the receiver. Then the sensor will
continue to monitor the lux level of environment. If the lux level is bigger than 60 lux, the sensor
is ready to repeat next ON/OFF activity
5、Random position: The light sensor resets first and send out an OFF signal to turn off
receiver. If the environment lux level is less than 15lux, the Sensor will send out a signal to turn
on the receiver. After 2, 5 or 8 hours (randomly chosen by programming), it will send out a signal
to turn off the receiver. Then the sensor will continue to monitor the lux level of environment. If
the lux level is bigger than 60 lux, the sensor is ready to repeat next ON/OFF activity