Aethon Inc. AEC2SOMENC1 Manuel D’Utilisation

Page de 24
Facility and Information Systems Requirements 
 
TUG
®
 Implementation Manual 
13
 
TUG Charging Station(s) 
 
Primary Power Input 
85-264VAC +/- 10% at <3.2A / 1.6A RMS at full load 
Fused at 6.3A, inrush (coldstart) <25A (peak) 
Max. 85-132VAC @ 47-63Hz 
Output Power on Skids 
29VDC @ 5.5A nominal, 6.5A peak 
Reverse voltage protection 
Thermal shutdown built-in 
Charging Current Limit 
Square (voltage drops as current peaks) 
Isolation 
>20Mohms at 100VDC, outputs to chassis Ground 
24V Ground tied to chassis ground (3rd prong of AC input) 
 
Dock height is 27”. Width is 12”. 
Power drop needs to be placed 
to the right or to the left of the 
dock. If placed above the dock,  
the power drop needs to be 
higher than 27” above the floor.