Fibar Group S.A. FGMS002 Manuel D’Utilisation

Page de 2
USA
Diagram 4 - Fibaro Motion Sensor installation.
Diagram 3 - preparing Fibaro Motion Sensor for operation.
TECHNICAL INFORMATION
VI. INSTALLATION NOTES
X. EARTHQUAKE DETECTOR MODE
V. DETECTION AREA AND WORKING CONDITIONS
VII. RESETTING THE FIBARO MOTION SENSOR
XI. SENSOR’S ORIENTATION IN SPACE
XII. LED VISUAL INDICATIONS AND SETTINGS
XIII. Z-WAVE RANGE TEST
VIII. OPERATING WITHIN THE Z-WAVE NETWORK
IX. ASSOCIATIONS
Power Supply:
EU directives compliance:
Recommended installation height: 
Operational Temperature:
Measured Temperature Range: 
Temperature Measuring 
Accuracy:
Light Intensity Measuring Range: 
Radio Protocol: 
Radio Frequency:
Range:
CR123A battery, 3.0V DC
RoHS 2011/65/EU
LVD 2006/95/EC
EMC 2004/108/EC
R&TTE 1999/5/EC
2,4m
0-40
o
C
-20 to 100
o
C
0,5
o
C (within 0
o
C-40
o
C range)
0-32000 LUX
Z-Wave
868,4 or 869,8 MHz EU;
908,4 or 916 MHz US;
921,4 or 919,8 MHz ANZ;
869 MHz RU;
up to 50 m outdoors
up to 30 m indoors
(depending on terrain and 
building structure)
Diagram 6 - Fibaro Motion Sensor’s motion detection area.
Diagram 5 -  Fibaro Motion Sensor’s proximity area.
I’M
READY
SPECIFICATIONS
The Fibaro Motion Sensor can be included into the Z-Wave network 
by using the B-button. 
1) Open the sensor’s casing by turning the cover counter-clockwise. 
Enclosure lock is marked with a dot.
2) Unlock battery by removing “I'm ready” stripe. 
3) Make sure the device is located within the direct range of the main 
controller. 
4) Set the main controller into learning mode (see main controller’s 
operating manual). 
5) Quickly, triple click the B-button - LED diode will glow blue to 
confirm setting into learning mode.
6) Fibaro Motion Sensor will be detected and included into the 
Z-Wave network. Wait for the main controller to configure the sensor.
7) If necessary, wake up the Motion Sensor by clicking the B-button. 
8) Close the sensor’s casing and install the device in desired place.
Diagram 1 - B-button.
Diagram 2 - Motion detector, light sensor, LED diode.
III. EXCLUDING SENSOR FROM THE Z-WAVE NETWORK
IV. SENSOR INSTALLATION
II. Z-WAVE NETWORK INCLUSION
B-BUTTON
SENSOR
1) Make sure tampering the device will not result in undesirable 
effects. Dismounting the sensor can trigger an alarm.
2) Open the sensor’s casing by turning the cover counter-clockwise. 
Enclosure lock is marked with a dot.
3) Make sure the sensor's battery is unlocked.
4) Set the main controller into learning mode (see main controller’s 
operating manual). 
5) Quickly, triple click the B-button, located inside Fibaro Motion 
Sensor’s casing. LED diode will glow blue confirming that the device 
has sent the Node Info Z-Wave command frame.
1) Include the device into the Z-Wave network (see p.II). Note that 
the inclusion process may be performed ONLY in direct range of the 
main controller.
2) Install the sensor’s holder in desired location.
3) Insert the Motion Sensor in its holder.
4) Test the sensor’s operation - check whether the LED diode 
indicates motion detection.
5) Test the Z-Wave network assuring the device is within range.
OPERATING MANUAL
FIBARO MOTION SENSOR
FGMS-001-USA-A-V1.02
The Fibaro Motion Sensor is a universal Z-Wave multi-sensor. Along 
with detecting motion the device measures the temperature and light 
intensity. The sensor has a built-in accelerometer to detect any 
tampering of the device. The Fibaro Motion Sensor is battery powe-
red device and designed to be installed quickly and easily on any 
surface. The LED indicator signals motion, temperature level, opera-
ting mode and can be used to see if device is within the Z-Wave 
network. The motion sensor can be used for lighting scenes and 
presence monitoring systems.
I. GLOSSARY OF TERMS
• 
adding - Z-Wave device learning mode, allowing to add the device 
to existing Z-Wave network.
• 
removing - Z-Wave device learning mode, allowing to remove the 
device from existing Z-Wave network.
• 
association (linking devices) - direct control of other devices within 
the Z-Wave network system.
• 
multi-channel association - controlling other multi-channel 
devices within the Z-Wave network.
• 
control command - type of Z-Wave network command enforcing 
change of device state.
• 
report command - type of Z-Wave network command holding an 
additional information, e.g. alarm state or measured temperature.
• 
alarm command - type of Z-Wave network command holding a 
warning of danger occurrence, e.g. fire alarm.
• 
multi-channel device - device having multiple endpoints - various 
device functions.
NOTE
The Fibaro Motion Sensor is a Security Enabled 
Z-Wave Plus product and a Security Enabled 
Z-Wave Controller must be used in order to fully 
utilize the product.
i
- Compatible with any Z-Wave+ controller.
- Works with other Z-Wave network devices, but as a battery 
  device it doesn’t take part in signal routing.
- Supports protected mode (Z-Wave network security mode) with 
  AES-128 encryption.
- Detects motion using a passive IR sensor.
- Measures the temperature.
- Measures the light intensity.
- Easy installation on a wall or any surface.
- Protected against tampering and theft - once vibrations are 
  detected, the notification is sent to the main controller.
- Alarms of movement and temperature are signaled by LED diode 
  blinking.
- Simple earthquake detector mode.
Fibaro Motion Sensor cannot be pointed at any source of heat (e.g. 
radiators, fireplaces, cookers, etc.) or at any source of light (direct 
sunlight, lamps). 
It’s not recommended to install the Motion Sensor in places prone to 
drafts and rooms with rapid fluctuations in air temperature. Sensor 
can be mounted using the included screw or the sticker.
Fibaro Motion Sensor allows for association of five groups:
1st Association Group „Lifeline” is a reporting group, assigned to 
the device status. Main Z-Wave+ network controller should be added 
to this group. The „Lifeline” group can handle only one device. If 
Fibaro Motion Sensor operates in protected mode, outgoing 
messages are always encrypted.
2nd Association Group „Motion” is assigned to the motion sensor. 
At the moment of motion detection or alarm state cancellation, nodes 
added to this group will receive control frames. The „Motion” group 
can handle up to five devices (one or multi-channel). If Fibaro Motion 
Sensor operates in protected mode, outgoing messages are 
encrypted, depending on whether the added node also operates in 
secure mode.
3rd Association Group „Tamper” is assigned to the tamper alarm. 
Once tampering is detected or cancelled,  nodes added to this group 
will receive alarm frames. The „Tamper” group can handle up to five 
devices (one or multi-channel). If Fibaro Motion Sensor operates in 
protected mode, outgoing messages are always encrypted.
4th Association Group „Motion BC” is assigned to the motion 
sensor. Once motion is detected or alarm state cancelled, nodes 
added to this group will receive report frames.  This group aims to 
provide backward compatibility with controllers not supporting the 
Z-Wave+ protocol. Only a main controller not supporting the 
Z-wave+ protocol should be added to this group. The „Motion BC” 
group can handle up to five devices (one or multi-channel). If Fibaro 
Motion Sensor operates in protected mode, outgoing messages are 
always encrypted.
5th Association Group „Tamper BC” is assigned to the tamper 
alarm. Once tampering is detected or cancelled, nodes added to this 
group will receive alarm frames. This group aims to provide 
backward compatibility with devices not supporting the Z-Wave+ 
protocol. Only nodes not supporting the Z-wave+ protocol should be 
added to this group. The „Tamper BC” group can handle up to five 
devices (one or multi-channel). If Fibaro Motion Sensor operates in 
protected mode, outgoing messages are always encrypted.
The Fibaro Motion Sensor allows for controlling 5 regular and 5 
multichannel devices per an association group, out of which 1 field is 
reserved for the Z-Wave network main controller.
Fibaro Motion Sensor can be configured to work as a simple 
earthquake detector, by setting the Parameter 24 value to 4. Reports 
with scale of the vibrations (in the Modified Mercalli Scale) will be 
sent at the time intervals specified in Parameter 22. First report will 
be sent immediately after vibrations have been detected. The 
minimum value of the vibrations, resulting in report being sent, can 
be defined in Parameter 20. Once the vibrations cease, reports will 
stop being sent. The Home Center 2 menu presents the earthquake 
detector measurements in the following way:
The Fibaro Motion Sensor has a built-in accelerometer. When the 
value of parameter 24 is set to 2 or 3, Z-Wave network controller will 
be informed on the Sensor’s orientation in space by sending report 
after triggering tamper alarm.
The Fibaro Motion Sensor is equipped with a LED diode for 
indicating sensor’s operating modes and alarms. In addition the LED 
indicator may inform of the Z-Wave network range and the current 
temperature.
LED indicator modes:
1) Motion Alarm’s colour will vary depending on the temperature. The 
colour and the signaling mode can be set in parameter 80.
2)  Tamper alarm is signaled with an alternating blinking in LAPD 
colours (red - blue - white).
3)  The Z-Wave Node Info command frame is signaled with glowing 
in blue. Node Info command frame is sent each time the device 
wakes up.
To enter MENU press and hold the B-button for 3 seconds. MENU 
levels will be signaled with the LED colours:
- VIOLET - Z-Wave network range tester
- YELLOW - sensor reset.
The Fibaro Motion Sensor has a built in Z-Wave network main 
controller’s range tester. Follow the below instructions to test the 
main controller’s range:
1) Press and hold the B-button for 2 to 4 seconds until the LED glows 
violet.
2) Release the B-button.
3) Press the B-button again, briefly.
4) LED will indicate the Z-Wave network’s range (range signaling 
modes described below).
5) To exit Z-Wave range test, press the B-button briefly.
By using association with Fibaro’s devices the Fibaro Motion Sensor 
may control another Z-Wave network device, e.g. a Dimmer, Relay 
Switch, Roller Shutter, RGBW Controller, Wall Plug, or a scene 
(scene only through the Home Center 2 main controller).
Fibaro Motion Sensor’s detection area is shown in diagram #6.
Fibaro Motion Sensor has to be installed in a corner of the room or 
perpendicularly to the doors.
Actual range of the sensor can be influenced by environment 
conditions. If false motion alarms are reported, check for any moving 
objects within the sensor’s detection area, such as trees blowing in 
the wind, cars passing by, windmills. False motion alarms may be 
caused by moving masses of air and heat as well. If the device 
keeps on reporting false alarms, despite eliminating all of the 
above-mentioned factors, install the device in another place.
The Fibaro Motion Sensor reset erases the memory, including all 
information on the Z-Wave network and the main controller.
Fibaro Motion Sensor reset procedure:
1) Make sure the battery works and is in place.
2) Press and hold the B-button for 4-6 seconds until the LED glows 
yellow signaling the 2nd option of the menu mode.
3) Release the B-button.
4) Again, press the B-button briefly.
Successful reset will be confirmed with the LED changing colour to 
red and fading.
Please use this procedure only in the event that the system primary 
controller is missing or otherwise inoperable.
Motion, temperature and light intensity values are presented in 
Home Center 2 menu with the following icons:
CAUTION  
Read this manual before attempting to install the 
device. Failure to observe recommendations included 
in this manual may be dangerous or cause a violation 
of the law. The manufacturer, Fibar Group S.A. will not 
be held responsible for any loss or damage resulting 
from not following the instructions of operating 
manual.
!
CAUTION
Work within local code height requirements for 
installation of the Fibaro Smoke Sensor. Take special 
precautions during installation and use tools and 
equipment in perfect working order. It’s recommended 
to observe ladders, lifts and other obstacles.
When handled carelessly or used in non-specified 
environment conditions, the device may not function 
properly. It’s highly recommended to take all safety 
precautions to ensure safety and property 
protection.
!
!
NOTE
Device reset will not remove it from the Z-Wave 
network main controller’s memory. However, 
removing the device from the Z-Wave network will 
reset Fibaro Motion Sensor automatically.
 
NOTE
Fibaro Motion Sensor capabilities will vary 
depending on the Z-Wave network controller. Certain 
functionalities of the Fibaro Motion Sensor may not 
be supported by some controllers. To make sure 
your Z-Wave network controller supports the Fibaro 
Motion Sensor, get in touch with its manufacturer.
3 m
0 m
7 m
0 m
5 m
5 m
7 m
NOTE 
Association allows for direct communication 
between Z-Wave network devices. Main controller 
does not take part in such communication. Using this 
mechanism, Fibaro Motion Sensor may communica-
te with other devices even when the main controller 
is damaged, e.g. in case of fire.
Fibaro Motion Sensor has a bulit in motion detector, temperature 
sensor and light intensity sensor, which make it a multi-channel 
device. In the Home Center 2 menu it will be presented as three 
devices, depending on the main controller software version. The 
sensor supports the secure mode. In this mode messages are 
encrypted, improving Z-Wave network safety level.
CAUTION
STICKER
CAUTION 
The Fibaro Motion Sensor is a battery-powered 
device. Dispose of properly, observing environmen-
tal protection rules.
!
CAUTION
Using batteries other than specified may result in 
explosion.
!
CAUTION
Use only batteries recommended by the manufactu-
rer and intended for use in the device. Using other 
batteries can be considered as breach of warranty 
terms.  
!
CAUTION  
Fibaro Motion Sensor may be included in protected 
mode (Z-Wave network security mode). In this mode 
communication takes place via encrypted 
messages. This improves the operating safety and 
reduces risk of unauthorized access to Z-Wave 
network and devices working within its range. 
Devices in protected mode can work together with 
standard mode devices.
!
i
i
Motion sensor
The primary function of Fibaro Motion Sensor is motion detection. 
The detector is a passive IR sensor. Motion Sensor operating 
parameters have been selected carefully and should not be changed 
by the user. However, it is possible to change sensitivity of the device 
by modifying parameter 1. You can also modify motion alarm 
cancellation delay with parameter 6.
Light sensor
Fibaro Motion Sensor has a built-in light sensor. Reports on the 
current light intensity are always sent to main Z-Wave network 
controller. Report can be triggered by change in light intensity 
(parameter 40) or after a specified time (parameter 42).
Temperature sensor
Fibaro Motion Sensor has a built-in temperature sensor. Reports on 
the current temperature level are always sent to main Z-Wave 
network controller. Report can be triggered by the change in 
temperature (parameter 60) or after a specified time (parameter 64).
Tamper alarm
Fibaro Motion Sensor has a tamper alarm, used to signal an attempt 
to dismantle the device. The main Z-Wave controller and other 
Z-Wave network devices are notified about tampering. The 
sensitivity of the tamper alarm may be modified in parameter 20.
i
When Fibaro Motion Sensor operates in secure mode, outgoing 
messages are encrypted, depending on whether the added node 
also works in secure mode.