CartaSense Ltd. LANUSG01 Manuel D’Utilisation
Mounting, installing and interconnecting
18
Version; 1.3
Lan cable length should not exceed 90 meters
5
.
3.3.3.2 Recommended Workmanship and Tips for Fixed USG Installation
IMPORTANT: the USG is NOT an outdoor unit.
USG must be kept in temperature between -20 and +60 degrees
DO NOT EXPOSE THE USG TO DIRECT SUNLIGHT.
Make sure the USG is protected from water and water spray
In case such environment cannot be met, an additional protecting case
should be employed.
should be employed.
CartaSense Fixed USG is usually installed in cold storage warehouses or
other facilities.
Make sure there is an electrical outlet within reach for powering the
USG.
Consider that the standard USG power cable length is 1.5m
Use an AC power extension if necessary. Properly install and fasten
the power extender. Install a dedicated power outlet if extending is
not allowed or not possible
The USG may be placed on a shelf, on a desk or mounted on the
wall.
The USG should be placed in a secure location however with an
easy access. If it is positioned in high locations, the LED indicators
should be visible.
Position properly the UHF antenna, as high as possible and as
remote as possible from a cellular antenna
The UHF antenna should preferably be located within a clear line of sight
between it and the Resident Sensors.
between it and the Resident Sensors.
3.3.3.3 Installation of Ethernet USG
Appendix-B: defines procedures and solutions for the installation of the
Ethernet USG under various LAN circumstances (corporate LAN, firewalls
etc.)
Appendix-B: defines procedures and solutions for the installation of the
Ethernet USG under various LAN circumstances (corporate LAN, firewalls
etc.)
5
LAN cables should be CAT5 type cables suited for telecom applications
The resident sensors in this example are used to monitor the environment as well as
repeaters.
repeaters.
Pay attention to the clear path the resident sensors are located avoiding interference.