www.idealindustries.com
WARNING: This is a current rated device. Use in applications involving
Amperage beyond its rating can be dangerous and cause electrical fires.
Wiring must comply with all applicable electrical codes.
TERMINOLOGY
24V Input: Incoming power feed from 24V source (DC Flex-Zone)
LOAD: Power output from Luminaire Controller to 24V DC LED Fixture input
24V Input: Incoming power feed from 24V source (DC Flex-Zone)
LOAD: Power output from Luminaire Controller to 24V DC LED Fixture input
DIM: 0-10 VDC dimming control output from Smart Connector to ballast
dimming input
dimming input
Power and Load Connections
Power
The 24V Input power is applied to the device once clipped onto the DC Flexzone grid.
Place the device in the desired location on an energized rail.
LOAD Connector
The LOAD Connector accepts 18 AWG copper conductors, solid or stranded (16 strands
The 24V Input power is applied to the device once clipped onto the DC Flexzone grid.
Place the device in the desired location on an energized rail.
LOAD Connector
The LOAD Connector accepts 18 AWG copper conductors, solid or stranded (16 strands
or less).
Use only one conductor per port and ensure that no copper is exposed on any of the
wires after installation.
24V DC Bus
LOAD
Connection
CC Connector
Fig. 1
0-10V Dimming