IDEAL INDUSTRIES ESCGRID1001 Manuel D’Utilisation

Page de 9
Product Manual 
ESCGRID1001 – LVDC Grid Luminaire Controller  
 
ND xxxx-x  04/2017 Users Manual – ESCGRID1001 LVDC Grid Luminaire Controller 
Page 2 
 
www.idealindustries.com 
 
 
WARNING: This is a current rated device. Use in applications involving 
Amperage beyond its rating can be dangerous and cause electrical fires. 
 
Wiring must comply with all applicable electrical codes. 
 
 
 
 
 
 
 
 
 
TERMINOLOGY 
  
24V Input: Incoming power feed from 24V source (DC Flex-Zone) 
LOAD: Power output from Luminaire Controller to 24V DC LED Fixture input 
DIM: 0-10 VDC dimming control output from Smart Connector to ballast 
dimming input 
  
Power and Load Connections 
 
 
Power 
The 24V Input power is applied to the device once clipped onto the DC Flexzone grid.  
Place the device in the desired location on an energized rail. 
LOAD Connector 
The LOAD Connector accepts 18 AWG copper conductors, solid or stranded (16 strands 
or less). 
Use only one conductor per port and ensure that no copper is exposed on any of the 
wires after installation. 
24V DC Bus 
LOAD 
Connection 
CC Connector 
Fig. 1 
0-10V Dimming