22  Troubleshooting 
 
Table 1 shows some troubleshooting tips to help resolve some issues often seen during setup 
 
Table 1 - Troubleshooting 
 
Symptoms 
Possible Cause 
Actions 
Details 
Ping 
192.168.1.1 
timeout 
POE cables or power 
cord  are not properly 
connected 
Check to see if both 
POE LEDs are on. 
  
AC LED not on  
– AC power cord 
not plugged 
 
POUT LED not on 
– POE Ethernet 
cable not connected to BOX RJ-45 
connector. 
Check to see if PC 
Link LED is on and 
blinking  
PC Ethernet cable not properly 
connected 
PC IP Address not on 
the same subnet of 
192.168.1.xx 
On DOS prompt, use 
ipconfig command to 
check if PC IP is 
properly configured 
Go back to network properties to 
reconfigure static IP 
Cannot ping 
box with new 
IP after re-
configure 
box’s IP 
New IP may not take 
effect 
Reset the box 
Power down/up to reboot the box 
Try to ping with old IP 
Try to ping and log in with old IP, 
then reconfigure IP 
Cannot 
establish 
radio link 
Does TX/RX on 
Does monitor show 
radio READY? 
If status shows radio not ready, try 
to turn tx on by typing “txon” on 
telnet shell. 
Does both CAR and 
EAR working on the 
same RF settings 
Use monitor to check 
the RF settings  
Checking region number, channel 
number to see if they are same 
Signal too Strong 
Lower TX Power 
Lowering TX Power by log into 
telnet shell, and adjust power by 
using “settxpwr” command 
Signal too weak 
Increase TX Power 
Increasing TX Power by log into 
telnet shell, and adjust power by 
using “settxpwr” command 
Interference 
– the 
current channel has 
strong interference or 
not clean 
Change to different 
channel  
Change to different channel in 
telnet shell 
Link 
Performance 
not good 
Link not balanced, 
signal too weak or 
strong 
Adjusting TX power  
Increasing or lowering TX power to 
adjust RSSI and MCS to a good 
range of -60dbm ~ -75dbm 
BTS or CPE 
is showing 
"No Valid 
Channel List" 
The registration info 
is incomplete, or the 
BTS or CPE cannot 
reach the database 
Double check 
registration info. 
Ensure the nodes can 