Computime Ltd. CTL35XXA Manuel D’Utilisation

Page de 18
ZigBee- Ready RF Transceiver Module CTL3585
4. Absolute Maximum Ratings
Parameter
Test Conditions
Min.
Max.
Unit
Regulator input voltage (VDD_PADS)
-0.3
+3.6
V
Voltage on any GPIO (PA[7:0], PB[7:0], 
PC[7:0]),
SWCLK,
nRESET,
VREG_OUT
-0.3
VDD_PADS
+0.3
V
Voltage on any GPIO pin (PA4, PA5, PB5, 
PB6, PB7, PC1), when used as an input to the 
general purpose ADC with the low voltage 
range selected
-0.3
2.0
V
Voltage on OSCA, OSCB, NC
-0.3
VDD_PADSA
+0.3
V
Storage temperature
-40
+85
°C
5. Recommended Operating Conditions 
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
Regulator input voltage (VDD_PADS)
2.1
3.6
V
Operating temperature range
-40
+85
°C
Moisture Sensitivity Level(MSL)
MSL3
6. Electrical Specifications
T=25
ć, VCC = 3.0V, Fo =2450MHz, if nothing else stated.
Parameter 
Condition / Note 
Min
Typ.
Max
Unit
RF Operating frequency 
Programmable in 5MHz  steps, 5 MHz 
steps for IEEE 802.15.4 compliance 
2.405
2.48
GHz
Number of channels 
For IEEE 802.15.4 compliance 
16
Channel spacing 
For IEEE 802.15.4 compliance 
5
MHz
Frequency stability 
+/-40
ppm
Transmit power 
Programmable from firmware 
+20
dBm
Sensitivity 
PER = 1% PER, 20byte packet 
defined
by IEEE 802.15.4 Boost 
mode
-100
dBm 
Adjacent channel rejection  +/-5 MHz 
IEEE 802.15.4 compliance at -82
dBm
35/35
dB 
Adjacent channel rejection +/-10 MHz 
IEEE 802.15.4 compliance at -82
dBm
40/40 dB 
Copyright © 2015 Computime Limited. All rights reserved.     