TEWS Elektronik GmbH & Co. KG MWT Manuel D’Utilisation
Technical Manual MW-T / Version: 1.6
2013-08-28
4. Technical Data
Environmental Conditions:
Temperature Range (operational)
Temperature Range (operational)
0°C..+40°C
Temperature Range
(Storage/Transport)
(Storage/Transport)
-20°C..+60°C
Relative Humidity
max. 85% (non condensing)
Degree of protection
IP54
Safety class
1
Mechanical Parameters MW-T:
Dimensions (HxBxT)
(Enclosure without handles)
Dimensions (HxBxT)
(Enclosure without handles)
600x540x350 mm³
Weight
50kg
Interfaces:
“USB“
“USB“
2x USB1.1 (non-insulated), max. cable length = 3m
“LAN“
1x 10/100baseT (electrically insulated)
“Ser.Interface“
alternatively 1x RS232/422/485 (electrically insulated)
(For service purposes only.)
standard baud rates: 300..115200
Inputs/Outputs:
Digital inputs “DIN1“
Digital inputs “DIN1“
3x, “0“=-3V..+5V “1“=+15V..+30V, input current 5mA,
non-insulated
non-insulated
Digital input “DIN2“
1x, “0“=0..+10V “1“=+16.8V..+30V, input current 10.5mA,
insulated
insulated
Digital outputs “DOUT“
4x, 24V active, max. 0.5A per output, max. 1A total,
non-insulated
non-insulated
Analog inputs “AIN“
3x, 4..20mA, input Ri=80Ohm + 0.7V, Umax=35V,
non-insulated
Analog outputs “AOUT“
4x, 4..20mA, load<350Ohm, electrically insulated
Optionally, the number of the inputs and outputs can be furthered.
Optionally, the inputs and outputs can be electrically insulated.
Optionally, the inputs and outputs can be electrically insulated.
EMC/Electrical Safety:
according to EN 61326-1 / EN 61010-1
Power Supply:
Cabinet, total
Cabinet, total
version dependend:
230VAC or 115VAC, 50/60Hz, max. 180W,
fuse: 3,15A (230VAC) or 6,3A (115VAC), time-lag
230VAC or 115VAC, 50/60Hz, max. 180W,
fuse: 3,15A (230VAC) or 6,3A (115VAC), time-lag
External components
(light barriers, IR-sensors, ..)
(light barriers, IR-sensors, ..)
24VDC, max. 1A, are supplied by the MW-T,
fuse: 1A time-lag
fuse: 1A time-lag
TEWS Elektronik GmbH & Co KG, Hamburg
9/24
EIS