- 3 - 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LED  Power 
Up 
Walk Test  Normal  Trouble 
Red 
Slow  
Blink 
ON  
Alarm 
ON  
Alarm 
Fast  
Blink 
Yellow  OFF 
ON  
Microwave 
ON  
Microwave  OFF 
Green 
OFF 
ON  
PIR 
ON  
PIR 
OFF 
 
Zones  
2
  Look-down  
18
  Lower  
46
  Intermediate  
36
  Long  
 
 
1.  Close the sensor and apply power to the sensor. Initialization is complete  
when the LED stops flashing slowly (about 30 seconds). 
2.  Walk through the detection area and observe the LED. 
3.  Adjust the microwave range as necessary to meet installation requirements. 
Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal 
operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature: 
Note:  During power up and walk test modes the LED is active regardless of the LED Enable/Disable Dip switch setting. 
 
Flashlight Feature: 
1.  Use a flashlight with a bright light beam, and stand within 4’ (1.2 m) of the sensor. 
2.  Swing the light beam past the sensor IR window 3-5 times, holding the beam on the  
window for 0.5 second each pass. 
The flashlight feature is only available for the first 24 hours after the first power up.