S.R. Smith LLC WPCPT6WIR Manuel D’Utilisation
79-15053-00 REV. D4
www.srsmith.com
Page 16 of 16
WPC FUNCTION CHART
Below is a chart of the WPC functionality based on the model number.
WPC1 - -
EXAMPLE:
WPC1-2X2X-1 is a 2 speed pump model with the Low Speed ON continuously until High
Speed is actuated by the Time Clock. Button 1/Circuit 1 is wired standard. Button 2/Circuit 2 is
wired as a Time Clock Bypass & JVA which actuates a JVA valve and turns on the High Speed
pump (if Time Clock is already ON, then this action will keep the High Speed ON even after the
Time Clock has Shut OFF) with the push of the Button 2 on the remote or flipping the Circuit 2
switch to ON. And this equipment is equipped with a Freeze Protect device which will turn on
the High Speed pump when outside temperatures drop near freezing.
X – Standard
1 – Freeze Protect
8 – Toggle for Lo Spd
Disc
9 – Standard T/C
Removed
1 – Freeze Protect
8 – Toggle for Lo Spd
Disc
9 – Standard T/C
Removed
X – Standard
X – Standard
1 – T/C Bypass
2 – T/C Bypass & JVA Valve
3 – WFPR added for Booster Pump
1 – T/C Bypass
2 – T/C Bypass & JVA Valve
3 – WFPR added for Booster Pump
X – Standard
3 – WFPR added for Booster
Pump
3 – WFPR added for Booster
Pump
X –1 Speed Pump – Standard
2 – 2 Speed Pump – 24/7 LO Speed,
T/C controls HI Speed
2 – 2 Speed Pump – 24/7 LO Speed,
T/C controls HI Speed
Pump
Features
Button 1
Features
Button 2
Features
Other
Options
Accessories