Shenzhen ITLONG Intelligent Technology CO. LTD HLD-DT-A Manuel D’Utilisation
26
power supply will be needed.
4.Floor signal collector fixed installation: According to the fixed hole
position on the signal collector box, find the proper place on the wall of
weak electrical well to install the collector. The floor signal collector
should be installed in every 3 floors or 15 floors, and power supply
should be provided around the collector. If the linkage interface in the
engine room is provided by intercom machine factory, the collector can
be installed in the engine room.
3.3 Devices Connection
1.The connection of button wires: cut off the signal wire of the floor
button(Figure 3-3-1),and connect the positive and negative poles with
the ribbon cable of buttons(red wire is positive, black wire is negative)
by wire connector(Figure3-3-2). Then insert the terminal of 8pin wires
into the corresponding floor button port. Finally insert the button wires
into the original place (Figure 3-3-3).
Figure
3-3-1
Figure 3-3-2
Figure
3-3-3
2.The connection of power supply: Fixed the power supply, then
connect the 2pin power line which is drawn from the power output with
the power interface of elevator access controller. Please note the poles
connection.