power supply will be needed.   
4.Floor  signal  collector  fixed  installation:  According  to  the  fixed  hole 
position on the signal collector box, find the proper place on the wall of 
weak  electrical  well  to  install  the  collector.  The  floor  signal  collector 
should  be  installed  in  every  3  floors  or  15  floors,  and  power  supply 
should  be  provided  around  the  collector.  If  the  linkage  interface  in  the 
engine room is provided by intercom machine factory, the collector can 
be installed in the engine room.     
3.3 Devices Connection 
1.The  connection  of  button  wires:  cut  off  the  signal  wire  of  the  floor 
button(Figure  3-3-1),and  connect  the  positive  and  negative  poles  with 
the ribbon cable of buttons(red wire is positive, black wire is negative) 
by wire connector(Figure3-3-2). Then insert the terminal of 8pin wires 
into the corresponding floor button port. Finally insert the button wires 
into the original place (Figure 3-3-3). 
 
   
Figure
 3-3-1                   
            Figure 3-3-2 
                         
Figure 
3-3-3   
 
2.The connection of power supply: Fixed the power supply, then 
connect the 2pin power line which is drawn from the power output with 
the power interface of elevator access controller. Please note the poles 
connection.