Blue Spark Technologies Inc. TT100 Manuel D’Utilisation
GREEN
Model Number
TT-100
Patch Dimensions
Length: 99.2mm, Height: 49.2mm, Thickness: 2.5mm
Patch Weight
4.5 grams
Patch Operating Life
24 hours
Patch Environmental Conditions
• Transport and Storage
• Use
-4 to 122 °F (-20 to 50 °C) / 15 - 95% RH (non-condensing) / atmospheric
pressure range of 700 hPA to 1,060 hPA
61 to 104 °F (16 to 40 °C) / 15 - 95% RH (non-condensing) / atmospheric pressure
range of 700 hPA to 1,060 hPA
Temperature Measurement Location
Axillary (under the arm) - app converts axillary temperature to body temperature
which is equivalent to temperature measurement taken orally
Temperature Range
87.0 °F - 109.3 °F (30.6 °C - 42.9 °C). Temperatures below this range will be
displayed in the app as "Lo". Temperatures above this range will be displayed in
the app as "Hi".
Temperature Indications
Less than 100.4 °F (38.0 °C) - GREEN
Equal to or greater than 100.4 °F (38.0 °C) - ORANGE
Equal to or greater than the user defined alert temperature - RED
Accuracy
Conforms with ASTM E1112-00 (2011); +/- 0.1 °C or +/- 0.2 °F over the temperature
range of the device
Display Resolution
0.1 °F (0.1 °C)
Response Time
Once applied to the underarm, the patch requires up to 3 minutes to reach a
stable reading
Transmission Distance
Patch will transmit up to 40 feet when applied to the underarm
Compatible Smart Devices
Smartphones and tablets with Bluetooth
®
4.0 running Apple
®
operating system
iOS 7.1 or later or Android™ operating system 4.3 or later. Visit temptraq.com for
a list of compatible devices.
Standards
ASTM E1112-00 (2011) standard for electronic thermometers
IEC 60601-1 Medical Design Standards, 3rd Edition
IEC 60601-1-2 Electromagnetic Compatibility
Bluetooth
®
Version 4.0
Radio Regulations
FCC Part 15
Industry Canada License exempt RSS standard(s)
ISO/IEC 60601-1-2 Electromagnetic Compatibility
Water Ingress Protection
IP22 - Protected from damage due to water dripping on the product.
Additional User Information
IMPORTANT:
Read instructions carefully
before use.
Type BF Applied Part
User Manual
Model TT-100
Important: Read instructions carefully before use.
High, prolonged fever requires medical attention.
If symptoms persist, contact your healthcare provider.
Introduction to TempTraq™
Welcome to
TempTraq™, hands-free temperature monitoring.
This guide is for your benefit to make sure you fully understand how to use the
TempTraq™
system.
TempTraq™ is a wearable, wireless, intelligent thermometer in the form of a one-time
use, disposable patch. The patch senses, records and transmits body temperature for 24 hours
via Bluetooth
®
Version 4.0. Temperature information from the patch is “read” using a smart
device (Apple
®
or Android™ with Bluetooth
®
Version 4.0 capability running the
TempTraq™ app).
TempTraq™ allows your child to rest when they are ill with an elevated temperature. There is no
need to disturb your child to take a temperature measurement so your child can rest and you can
have the peace of mind knowing your child’s temperature.
have the peace of mind knowing your child’s temperature.
Clinical Temperature Information
Normal body temperature is not a single temperature, but a range of temperatures
influenced by age, time of day, and measurement site. We recommend that you
take the temperatures of your family members when they are well to establish their
normal body temperature. Many people may not have an elevated temperature
when they are sick. These include, but are not limited to, infants under 90 days
old, people on steroids, antibiotics or antipyretics (acetaminophen, ibuprofen, and
aspirin), people with compromised immune systems (including the elderly and those
having HIV/AIDS). See your doctor if you feel someone is ill even if their temperature
is not elevated.
influenced by age, time of day, and measurement site. We recommend that you
take the temperatures of your family members when they are well to establish their
normal body temperature. Many people may not have an elevated temperature
when they are sick. These include, but are not limited to, infants under 90 days
old, people on steroids, antibiotics or antipyretics (acetaminophen, ibuprofen, and
aspirin), people with compromised immune systems (including the elderly and those
having HIV/AIDS). See your doctor if you feel someone is ill even if their temperature
is not elevated.
A doctor should be consulted in the following situations where fever is present:
vomiting, diarrhea, changes in appetite, activity or breathing, or with children who
are irritable, lethargic or unusually sleepy.
vomiting, diarrhea, changes in appetite, activity or breathing, or with children who
are irritable, lethargic or unusually sleepy.
TempTraq Temperature Measurement
TempTraq™ measures under-the-arm "axillary" temperature and converts this
temperature to display body temperature which is equivalent to a temperature
measurement taken orally.
Fever Guidance
The
TempTraq™ app uses color coding to aid the user:
indicates a temperature is in the normal range.
indicates a possible fever of 100.4°F (38.0°C) or higher.
indicates a temperature equal to or higher than the alert
temperature that you selected.
Warnings and Precautions
When using this product always follow these basic safety precautions to insure that the patch accurately
reads temperature and to avoid skin irritation. Failure to follow these precautions could result in
inaccurate temperature readings resulting in delay in treatment, or could result in skin irritation and
mild discomfort.
DO NOT use the patch for any other purpose besides measuring human body temperature.
DO NOT place the patch over wounds, sores or abrasions.
DO NOT excessively bend or twist the TempTraq™ patch prior to application.
DO NOT immerse the patch in water. Patch may be removed for a bath or shower and
then re-applied afterwards.
DO NOT use the patch if it has been damaged or immersed in water.
DO NOT attempt to take apart the patch; there are no user serviceable parts.
DO NOT wear successive patches under the same arm. When removing one patch and
starting another, place the second patch on the other side of the body.
Consult with your doctor before using on children under 2 years of age.
Patch adhesive may irritate sensitive skin. Contact your doctor if irritation persists.
For Best Results
• Apply the patch to clean dry skin
• The sensor - the corner marked with “underarm” - must be positioned in the
center of the armpit.
• The arm should be relaxed along the side of the body to enclose the
TempTraq™
sensor in the armpit.
• Temperature measurements can be affected by ambient temperatures,
particularly if the patch is exposed to cold ambient temperatures.
• Temperature data from the
TempTraq™ patch can be read up to 40 feet away
depending upon a number of factors, including obstructions between the patch
and the smart device, and the position of the patch on the body. For improved
performance, move the smart device closer to the
TempTraq™ patch.
Troubleshooting Guide
Specifications
Problem
Troubleshooting Hints
Patch ID is not visible in the app
when setting up a new profile
• Patch may not be activated. Press button on patch to
activate.
App is showing "Out of Range" for
a patch
• Move the smart device running the
TempTraq™ app closer
to the patch. The patch can send temperature data up to
40ft. This distance is reduced by walls and objects between
the patch and the smart device.
Temperatures from the patch are
lower than expected
• Check to make sure that the patch is properly positioned
with the sensor - marked "underarm" - correctly positioned
in the armpit as shown in the instructions for use.
• Lower than expected temperature readings can also be
caused by exposure to cold ambient temperatures, for
example, when the arm is raised exposing the patch to cold
ambient temperatures.
• Confirm the patch is correctly reading temperature by
measuring oral temperature with a digital thermometer.
Temperatures from the patch are
higher than expected.
• Confirm the patch is correctly reading temperature by
measuring oral temperature with a digital thermometer.
No audible alert is received
from the smart device when the
device is out of range or when a
temperature alert is generated.
• Check to insure that the phone volume is set to an audible
level and is not set to mute.
• Check settings for the app to insure that notifications are
enabled and sound is enabled for notifications.
• Note that the audible alert only sounds for a short period.
The visual notification remains active in the app until
canceled by the user.
No alert is received when
temperature measured by the
patch exceeds the user set alert
level.
• Check to make sure that the smart device running the app
is in range of the patch. A temperature alert will not be
generated if the smart device is out of range of the patch.
• Check to insure that the app is running. No alerts will be
generated if the app is not running.
Warranty
FCC Statement and Legal Notices
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference,
and (2) this device must accept any interference received including interference that may cause undesired operation.
FCC WARNING: any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate
this equipment under FCC regulations.
NOTE: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
and (2) this device must accept any interference received including interference that may cause undesired operation.
FCC WARNING: any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate
this equipment under FCC regulations.
NOTE: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit difference from that to which
the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
© 2015 Blue Spark Technologies, Inc.
TempTraq™ and other related marks are owned by Blue Spark Technologies, Inc.
TempTraq™ and other related marks are owned by Blue Spark Technologies, Inc.
Protected by U.S. Patent Nos. 8,029,927;8,268,475;8,722,235. Other foreign patents pending.
All other trademarks are property of their respective owners.
TempTraq™ warrants each new TempTraq™ patch against defects in materials or
workmanship for a period of one year from the date of purchase, and agrees to replace
any defective product without charge.
IMPORTANT:
This warranty does not cover damage resulting from accident, misuse or abuse, or lack of
This warranty does not cover damage resulting from accident, misuse or abuse, or lack of
reasonable care. No responsibility is assumed for any special, incidental or consequential
damages. In order to obtain warranty replacement, simply call
TempTraq™ Customer
Care at 1 (440) 249-5440 for return instructions.
NOTE:
No other warranty, written or verbal is authorized by
No other warranty, written or verbal is authorized by
TempTraq™. This warranty gives
you specific legal rights and you may also have other rights which vary from state to
state. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above exclusion and limitations may not apply to you.
WARNING: No modification of this equipment is allowed.
The device or its components are not intended to be serviced,
The device or its components are not intended to be serviced,
replaced, or repaired.
Device is powered by a 3V non-rechargeable battery. Not
Device is powered by a 3V non-rechargeable battery. Not
intended to be recharged, serviced, replaced, or repaired.
The device is single use only. Do not reuse
May be safely applied to self or used on others.
May be discarded in common household waste.
The device is single use only. Do not reuse
May be safely applied to self or used on others.
May be discarded in common household waste.
Need More?
VISIT
TEMPTRAQ.COM
CALL 1 (440) 249-5440
Intended Use
The wireless thermometer, model TT-100, is a battery-operated electronic device with an intended
use of measuring human body temperature precisely. This device is single-use and intended for
armpit temperature measurement for persons of all age.
ORANGE
RED