 Outputs
Internally, the output lines are provided with Power Mosfet. Using an 
external power supply, the output current must not exceed 1.2A/30V 
continuous or 5A/30V (0.5 sec) peak current for inductive loads. Using 
the internal power supply, the output current must not exceed 30mA.
Usually the OUT1 is dedicated to the Door Electro lock.
Usually the OUT2 is dedicated to the busy lamp.
Outputs can be also used as general purpose outputs.
Temaline recommends that you establish an electrical environment where 
the cables are well separated, even at short runs, especially to the power 
cables or external cables which can be essentially subjected to interference 
or lightning.
External relays powered by the reader
When the load exceeds the max internal current of 30 mA you must use an 
external relay.
Figure 24 Relays OUT