SETUP
1 - Connect the spout to the well. 3 spouts are
supplied with the well watch with standard male
pipe threads 1/2”, 3/4”, and 1”. The spouts are
designed to be threaded into vent holes near
the end of the well. It is not required that the
spout be vertical or near the center of the well.
It is also permissible to use adapter fittings to
clear obstructions. Assemble the fittings from
the well to the spout remembering to place the
plastic ring nut on the spout before screwing it
in place. The spout should not be more than
hand tight.